1 20Ton H Coal Gas Fired Steam Boiler Price

1 20Ton H Coal Gas Fired Steam Boiler Price

Car accessories types of complex processing, such as the interior wall Peng, floor, seats, instrument panels, sound systems, many processes required in a high temperature environment, the temperature becomes optional metrics wind Visteon hot water boiler. It is reported that Dongfeng Visteon existing boiler equipment can not reach the growing production needs, the introduction of fast boiler production of two parties often piezoelectric hot water boiler (CWDR1.8-95 / 70-II) in 2017.

Gas 1 20ton h coal fired steam boiler price load changes in the water level of air pressure adjustment What happens next: load fluctuation gas steam boiler water level of the air pressure regulating what impact the boiler load refers to the amount of steam is supplied outside?. When the variation amount of steam needed outside world, boiler pressure, temperature, level crossing will move. When the load increases, the pressure drop in the water level is low, the air supply should be increased and the amount of coal. While enhanced combustion, and gradually increase the amount of water to maintain normal air pressure and water level. When reducing the load, the air pressure is high the water level rises, the amount of coal should be reduced and the air volume, reduce combustion, then the appropriate amount of water to reduce or suspend the water supply, the air pressure and water level in the stable nominal range, then press normally combustion and to adjust the amount of water. When reducing the load, the pressure rise when the water level is low, to increase the amount of water should be, until the water level returns to normal, then the need for air pressure changes and the load situation, and to adjust the combustion water.

A heated boiler is called a boiler. Heat transfer oil, also known as organic heat carrier or heat medium oil, has been used as intermediate heat transfer medium in industrial heat transfer for more than 50 years. Based on the idea of forced cycle design, a once-through boiler is developed. Generally, coal, oil and steam are used as fuel, heat conduction oil is used as the medium, hot oil circulation pump is used to force the medium into liquid phase circulation, heat energy is transmitted to the heating equipment and then returned to the heating furnace for re-heating. High operating temperature at low pressure, and high precision control for medium operation. The heat utilization rate of the system is high, and the transportation and maintenance are convenient. The closed circulation heat supply is connected with the atmosphere, can extend the service life of the boiler, liquid phase or gas phase transportation heating. The boiler adopts three-way coil design, the system sets the expansion water tank, and realizes low-pressure and high-temperature heating. The coil structure is adopted, the heating surface is sufficient, and the expansion is fully absorbed. Imported low-NOX combustion machine, combustion charge, belongs to environmental protection products. Boiler can choose advanced touch screen computer controller and digital computer controller automatic control system. With automatic temperature regulation, automatic ignition, and differential pressure, overtemperature, quenching protection. Boiler manufacturing standards, strictly in accordance with the relevant national standards. Pot The use of furnace water quality requirements: some users believe that as long as the boiler to maintain water can be, the water quality is not a choice. In fact, the quality of water on the boiler or have an impact, the editor recommends that you choose clean tap water. Because if there are impurities in the water, the use of this impurity water will have some impact on the equipment. The impurities form a thick layer of scale on the inner wall of the boiler. Scale will gradually thicken with time, and the accumulation of thickness will affect its heat transfer efficiency, resulting in a waste of energy consumption. If the scale appears, it should be cleaned up in time, so that the heat can be concentrated in the scale, which is not easy to emit. .

After the gas hot water boiler hot water boiler vaporization emergency 1. Vaporization handler circulating pump stops abnormally pump failure caused by: ① blower stops running immediately. ② immediately open the door, take measures to pressure the fire, lift the chute gate, cutting off the supply of coal grate. ③ In the case of boiler pressure not greater than 0.6MPa (600KPa), the exhaust valve to follow, only a sharp rise in pressure in the boiler deflated, used only relief exceeds 0.9MPa, and the exhaust process to be carried out slowly, prevention boiler due to loss of pressure and more violently again vaporized. ④ close the boiler water, water main gas valve. ⑤ open stop valve recirculation line, to ensure that the water supply pipe velocity convection heating surface (economizer) to prevent re-vaporization of the economizer. ⑥ The operation of the above operation, at the same time to pay the boiler to reduce the boiler water temperature and the furnace pressure. ⑦ After the boiler pressure is normal, i.e., opening the standby circulating pump, into the normal combustion. 2. Treatment failure or sudden loss of power boiler vaporization of power: ① immediately open the door, lift the coal chute slide gate to take pressure fire measures to reduce the oven temperature. ② Grate with the fastest speed in order in the shortest time to fire onto the slag tap. ③ the degree of treatment in the first case. Once a short time can not supply heating network system, antifreeze should take emergency measures. 3. Due to excessive heat boiler boiler vaporization process: ① the immediate closure of the drum, induced draft fan. ② immediately open the door, take measures to pressure the fire, lift the supply of coal chute slide gate, off of coal, while the grate into fast gear. ③ In the case confirmed the presence of water, the boiler can supply water to the boiler body, boiler out of the water while closing the main valve. ④ Open line stop valve recirculation pump to ensure water velocity convection heating surface of the pipe, to prevent the economizer again vaporized. ⑤ Open circulating pump with jog mode, jog each time less than 30 seconds, again less than one minute jog interval. Jog purpose is to reduce the boiler water temperature, while preventing a large amount of steam into the pipeline system. ⑥ back into place after the safety valve, circulating pump running, and then the normal burning stove. 4. Water boiler system run vaporization process due to water loss, loss of pressure caused by: ① immediately closed drum, induced draft fan. ② out of the water while closing the main valve and the boiler circulating pump. ③ take the same measures to cool the furnace tube described above. ④ Open stop valve recirculation line. ⑤ rely exhaust valve until the safety valve back into place. ⑥ until the boiler water temperature drops below 50 ℃, when the temperature of the furnace temperature less number 200 ℃, again within the boiler feed water, water course to be carried out slowly, to prevent harm to the boiler when the temperature is too large. ⑦ After processing leakage fault, the system time to the replenishment, and out of the water boiler always open the valve, and the circulating pump, and then normal combustion.

Free Chat

About Us

Contact Us