1 25T 2T Oil Fired Steam Boiler

1 25T 2T Oil Fired Steam Boiler

10 tons of gas turbine 1 25t 2t fired steam boiler burner it currently requires 10 tons of steam gas boiler steam boiler there are two types WNS10-1.25-Q SZS10-1.25-Q, and two kinds, i.e., three horizontal wet return back structure and vertical type double drum "D" type arrangement quick water tube boiler. It consists of upper and lower drum, membrane wall, superheater, economizer and convection bank composition, the burner disposed on the front wall, the fuel combustion in the furnace, the flue gas through the first convection bank, superheater, a second convection economizer tubes and into the chimney. 10 tons of gas boiler burners have split and one-piece points, integrated burner fan I see are axial fans, centrifugal fans with split, 90% of the 10 tons of gas boiler burner all-in-one, as to form two burner what a good way, this has yet to be explored. SZS10-1.25-Q has the following features in gas boiler: The product has the following characteristics: ⑴ This double boiler drum "D" type arrangement, a compact, small footprint, good flame fullness. ⑵ boiler lower support mode can be free to expand upwards. ⑶ using membrane wall furnace wall structure which reduces maintenance work and use of refractory bricks. This boiler ⑷ fender an airtight closed welded structure, good sealing furnace wall; outer layer of pressed boards, appearance, beautiful. ⑸ this boiler furnace inspection hole is provided for the use, maintenance provides a great convenience. Roof has explosion-proof doors. This quick ⑹ boiler structure can effectively shorten the installation cycle. ⑺ high thermal resistance material as a heat insulating layer, good insulation properties. ⑻ economizer arranged tail, can effectively control the exhaust gas temperature, high thermal efficiency of the boiler. ⑼ whole boiler steel holder on a strong base, convenient installation and transportation. ⑽ boiler heating surface has a surplus, soft drinks and large enough space to ensure the stability of the boiler parameters. ⑾ using automatic burner, combustion efficiency and an ignition control program and overpressure, flame protection. ⑿ continuous electrically adjustable water supply, and having a low water level alarm, the protection function chain. ⒀ using spray desuperheater, sensitive temperature adjustment, temperature control large amplitude. Second, the structure Introduction boiler 1, the main evaporation rated specifications: D = 10t / h of superheated steam temperature: t = 300 ℃ superheated steam pressure: P = 1.25MPa water temperature: tgs = 20 ℃ (except normal saline) boiler efficiency: η = 92.6% exhaust temperature: tpy = 136.3 ℃ desuperheater tYPE: hydrostatic pressure test boiler desuperheater spray: 1.75 MPa number of valve: drum 2 PN2.5, DN80 full open spring valve overheating an outlet header PN2.5, DN50 full open spring valve design of the fuel: 0 light diesel oil (Qydw = 41870kJ / kg); consumption 749.9kg / h of natural gas (Qydw = 37060kJ / Nm3); 847.3 consumption Nm3 / h

What are the precautions in the loading and installation of gas-fired 1 25t 2t fired steam boilers?

Gas-fired steam boilers are a very wide range of special equipments, widely used in food, chemical, paper, textile, construction and other industries. In the process of loading and installing a gas steam boiler, some problems must be paid attention, otherwise it may cause a certain degree of economic loss.

1. Pay attention to the following matters during the loading and unloading and handling of gas-fired boilers: the lifting capacity of the lifting equipment should match the weight of the lifting boiler. The lifting lug on the boiler with the lifting lugs that cannot be used for lifting can not be used for lifting. The length of the steel cord should be reasonably selected to avoid the scratching of the furnace due to the improper length of the steel cord. The boiler must be protected from any damage during handling and handling.

2. Reserves for maintenance space When installing boilers, ensure that there is sufficient maintenance space around the boiler.

3. Setting and precautions for the base and base of the gas steam boiler The boiler body must be installed on the basis of 100-150mm above the floor of the boiler room. It must be confirmed with the technical personnel of the boiler manufacturing company in advance and constructed according to the basic drawings. The anchor bolts must be reserved on the foundation. The foundation shall be capable of withstanding the maximum weight of the boiler and the amount of water it holds. When installing the base, you must first position it. After positioning, adjust to the same length of the two diagonals of the base, and then tighten all the fixing bolts. The installation of the base is carried out with reference to the reference line.

4, general precautions Be careful not to tilt and impact the boiler and accessories too much. No combustibles can be placed around the boiler. Do not use oil and water to smother the boiler. The boiler should normally be installed in a separate boiler room. The new gas-fired boiler room should not be connected to the house. The boiler room shall not be connected to Class A, Class B and Category C fire hazard rooms using flammable liquids. If connected to other production plants, the application firewall is separated.

5. The fire resistance grade and fire protection requirements of the boiler house building shall comply with the requirements of the Code for Fire Protection of Building Design and the Code for Fire Protection Design of High-rise Civil Buildings. The ground of the gas steam boiler room should be flat, non-flammable, no water accumulation, and the foundation load should meet the requirements. The power supply voltage of the gas steam boiler room should be stable to avoid causing the electrical components to burn out. If the voltage is unstable, it is recommended to install a voltage regulator. Ventilation equipment should be installed in the boiler room, and the boiler should be kept at room temperature below 50 °.

Classification is the use of fuel oil-fired boiler and practical, this boiler is the boiler variety of diesel fuel and waste oil, his overall construction and arrangement of the gas boiler is similar to a common classification of mechanical and steam materialized style.

Shanxi Province is located in China's western areas north of the Loess Plateau, the terrain finished solid, rich products. Thanks to energy supply and price advantage of coal, coke, metallurgy, electric power and other coal industry, the rapid rise of the formation of Shanxi coal-based economies of resource-based industries.

Shanxi Province, but had coal and Xing, but also because of the coal and sleepy. According to the report, "2017, Shanxi Province, coal accounted for the proportion of energy consumption up to 84.6%, higher than the national average of 24 percent, it is 2.9 times as much as the global average of Shanxi to 1.6% of the national land area, consuming about 10% of national coal amount. for Shanxi, winning the battle of blue sky, coal pollution can be effectively controlled is the key.

According to the "Blue Sky Battle Shanxi three-year action plan," issued in July this year (hereinafter referred to as "" Shanxi three-year action plan '') planning requirements, by 2020, sulfur dioxide, total nitrogen oxide emissions are lower than in 2015 more than 20%, compared to strive average concentration of sulfur dioxide in 2015 fell about 50%. Among them, 2020, total coal consumption in 8 cities in key areas to achieve negative growth, the province's coal consumption in primary energy consumption share dropped to 80%, the proportion of the province's coal consumption of coal accounts for more than 55%.

According to Shanxi Province Bureau of Statistics latest data, as of the end of August this year, Shanxi Province, the outgoing power 50.67 billion kwh, up 21.1%; the first half of Shanxi new energy consumptive power grid to complete 15.6 billion kilowatts, an increase of 58.2%, new energy abandoned consumption fell 90.6% year on year, abandoned electricity rate fell 10.2 percentage points.

The past two years the province shut down 52 coal mines, quit production capacity 45.9 million tons, subtract coal production capacity of 9.25 million tons per year, the completion of energy-saving 18 million kilowatts of coal-fired power plants, coal-fired power plants province's average coal consumption of electricity of 320 grams per kilowatt-hour of standard coal. In the first half of this year, the province's above-scale industrial Shanxi coal industrial added value increased only 0.8%.