1 Ton Oil Steam Boiler In New Zealand

1 Ton Oil Steam Boiler In New Zealand

Why should the petroleum industry use 1 ton steam boiler in new zealands

It is well known that the petroleum and petrochemical industry is inseparable from the use of large-scale steam boilers for thermal energy conversion or filtration use. The reason why steam-type boilers will be selected for processing use. Because not only high thermal energy but also energy-saving and environmental protection can meet the needs of petroleum and petrochemical industry. Professional steam boiler can not only help the petrochemical industry to process smoothly, but also help enterprises to produce huge economic benefits to improve the production of petroleum processing. Let's follow the editor to see why steam boilers are used in the oil industry:

1, it can save processing costs more effectively because steam boilers can save energy and environmental protection in the process of processing and use to reduce power consumption, so the use of the corresponding in the petroleum and petrochemical industry can reduce the larger cost investment. Moreover, steam boilers use electric energy to process and use, so they can effectively save a lot of energy consumption and help enterprises reduce costs. Reducing the cost can be more beneficial to the petrochemical industry to use a large number of processing to improve economic efficiency.

2, the reason why steam boilers are selected for long-term processing and use in the oil industry with high safety and stability of steam pressure is also because steam boilers are stable in operation and can carry out effective range control. Moreover, the boiler can control itself in the safe operation of steam pressure value, and ensure the safety and stability of the equipment in the process of operation. Therefore, it is especially suitable for petroleum and petrochemical industry with large processing capacity and long duration.

3, boiler energy-saving technology highlights that petroleum needs the conversion of boiler thermal energy in the refining and chemical process to carry out normally, and steam boiler has unique energy-saving technology and can automatically feed water through frequency conversion technology. Moreover, the steam temperature and pressure can be automatically adjusted under stable conditions, so it can be more energy-saving and stable compared with the continuous working process, and it can also save energy and reduce emissions while ensuring the normal supply of petroleum processing at the same time.

Such as hotel Home Hotel Group is one of the three major brands, in 300 cities in the country has nearly 2,000 hotels. Home Inns has won China Golden Pillow Award for Best Chinese economy hotel chain brand award, in 2014, Home Inns brand value of $ 420 million of selected China's top 100 brands. April 4, 2016, BTG hotel groups such as the privatization of the hotel purchase transaction has been completed delivery. In mid-2016, as a Beijing hotel with our preliminary communication, the urgent need two boilers work of heating and hot water supply. I related technical engineers and recommend it to calculate the number and size of the boiler on the hotel room as hotel Willy sharp V6-99 two models.

What companies need to use 1 ton steam boiler in new zealand steam boiler uses a very broad, both in production and life plays a very important role. The use of a wide boiler, industrial and civil division, the following companies will be used in steam boilers: steam boiler through the heat exchanger, the heat exchange steam water supply, water heating, then heating, heating, bathing, production and other uses. Food industry: aspects of food processing, medical industry and is used as filling bottles and other disinfecting, the food industry can be used as steamed meat, meals. Wine also used steam. The petrochemical industry, the oil and steam may be heated to increase the flowability. Petrochemical manufacturing process also with steam. Manufacturers, with more extensive use of the steam, such as a sheet of foam insulation, heating with steam production foamed material production. Furniture made of wood to use steam drying, in order to make furniture. Filling brick building is also used for drying steam, can also generate electricity and so on. Washing Ironing industry: dry-cleaning machine, dryer, washing machine, dryer, ironing machine, iron and other equipment for the use of packaging machinery industry: labeling machines, standard sets of supporting the use of bio-chemical industry: a fermentation tank, reactor, supporting sandwich pot, mixer, emulsifier and other devices used food machinery industry: tofu machine, steamer, pot sterilization, packaging machines, coating equipment, sealing machine and other equipment for use in other industries :( oil, automobile) steam cleaning industry, (hotels, dormitories, schools) steam or hot water supply, (bridges, railways) concrete curing, etc.

Determine the location of the 1 ton steam boiler in new zealand room siting what issues need attention 1, boiler room refers to the building design boiler and ancillary equipment, water treatment facilities, pumps and sub-steam (water) tank and the like. Boiler should be separate and independent from other buildings. Boiler room should not be set directly in crowded places (such as public bathrooms, classrooms, restaurants, auditoriums, shopping malls, waiting rooms, etc.), or at the top, bottom, or the immediate neighborhood of the main evacuation port on both sides. 2, the new boiler room should not be connected to the house. 3, provided in the boiler room such as a semi basement layers or high buildings or the first layer must meet the following conditions: (1) each steam boiler rated evaporation does not exceed 10t / h, steam pressure does not exceed the rated 1.6MPa; rated each water boiler (including direct fired absorption chiller-room unit) does not exceed the output 7MW, the rated water temperature ≤95 ℃. (2) Each steam boiler must have a reliable overpressure protection interlocking means interlock protection device and the low water level. (3) accessories and safety interlock protection device for each boiler to regular maintenance and testing to ensure that sensitive and reliable. (4) the building structure between the boiler should have the appropriate proof Measures. (5) operate independently of the fireman who must hold the appropriate level of operating permits fireman, boiler and continuous operation of the same class more than five years, has not been an accident. (6) There must be safe evacuation routes. 4, should not be located in the boiler room or a high-rise multi-story building basement, an intermediate floor or roof, but the conditions required setting time, shall meet the requirements of paragraph 3, the first gist of the present, should meet the following conditions, and former boiler room should be set prior consent districts of the city and over special equipment safety supervision agency: (1) steam boilers rated evaporation each no more than 4t / h, rated steam pressure does not exceed 1.6MPa; each heat rated water boiler (including direct fired absorption chiller-room unit) does not exceed the output of 2.8MW, the rated water temperature ≤95 ℃. (2) must be light oil, city gas, natural gas as fuel or electric heating boiler. Underground boiler room non LPG gaseous fuel or a density greater than 0.75. Connection (3) using a fuel supply pipe welding backing. In addition, when set in the basement boiler room, blowdown or appropriate measures should be set up sewage. When using gas as fuel, the exhaust system is also provided accident. 5, not connected to the boiler room A, (B) and (C) a liquid combustible fire risk room. If connected to other production plants, application firewall separated. Waste heat boiler is not so limited. Boiler production plant belongs to class D, between the fuel tank, between the pump delivery room Class C production, between the gas regulator belonging to the delivery room A of production. 6, between the outer wall or roof of the boiler should be at least equivalent to 10% of the area between the boiler pressure relief area (such as windows, skylights, shutters, etc.), and the relief port should avoid crowded places. 7, boiler room should be equipped with emergency lighting and evacuation signs, emergency lighting voltage shall not exceed 36V.

Free Chat

About Us

Contact Us