1500 Kg Hr Heavy Oil Type Steam Boiler

1500 Kg Hr Heavy Oil Type Steam Boiler

To get industrial gas boiler safe operation must be done to check the work of industrial gas-fired boiler pressure vessel belongs, in our country there are strict and clear standards of production and operation. In particular boiler in operation, should always pay attention to whether the safe operation of the boiler, auxiliary equipment and operation of each respective instrument valves is stable. Therefore, gas 1500 kg hr type steam boiler room is necessary to establish a sound system of inspection tours and boiler room equipment maintenance system. First, natural gas boiler room mobile inspection system 1, in order to ensure the normal operation of the boiler and its accessory equipment, timely detection of problems, fireman on duty personnel at least once every half hour tour inspection. 2. Check gas boiler burners, pressure gauge, thermometer, circulation pump, water supply pump, water softening, safety accessories, an instrument, secondary instrument is functioning properly. 3, check whether the abnormal changes in various types of signal lights. 4, check the water level in the tank gas boiler, feed pumps, circulating pump and motor bearing temperature and pump lubricating parts are normal. 5, check the position of the gas valve and the steam boiler feedwater pressure switch valve is normal. 6, mobile inspection found problems in time, and test results recorded in the log boiler and accessory equipment inside. Second, gas-fired equipment maintenance system 1, two gas-fired boiler on the pressure gauge value is not the same timely maintenance, to ensure reflect the actual operation of the boiler pressure. 2, gas boiler pressure gauge damage, when the dial is not clear, timely replacement. 3, rotating machinery lubricating oil passage remains open, the oil cup to maintain a certain oil level. 4, run, run, drip, leak repair valves can be repaired, replaced. 5, inspection, maintenance and feed pumps, circulating pumps and pump valves open is flexible, single-stream if the door is closed tight. 6. Check the gas-fired secondary instrument is normal. 7, to remove dust on the equipment and the accessory device. 8, check the gas boiler safety valve manually turn on the water after closed trials are tight. Automatically turn on the water, blowing off steam at least once a week. 9, pressure gauges operate properly flushed at least once a week. Trap maintenance once a month. 10, over-temperature, overpressure alarms, overpressure interlock device checks at least once a month, and maintenance. Gas boiler pressure gauge, water level gauge and a safety valve are the three safety accessories on the gas steam boiler, with particular attention.

Hot water boiler in the school dormitory and classroom building are generally used for central heating, drinking water and bathing water aspects of teachers and students and so on. Shanxi Linxian County high school is an important educational school personnel training for the community. 2017, the school responded positively to national coal to gas and other environmental policies, but also to provide students with a more favorable living and learning environment, the school decided to phase out conventional coal-fired boilers, clean and environmentally friendly replacement for the gas boiler. After getting to know and choose the boiler industry, major companies, determined cooperation with professional production of clean fuel boiler fast boiler-by-side to provide a fast 4.2MW integrated condensing gas hot water boiler (WNS4.2-1.0 / 115 / 70-YQ).

Pressure fire operations and precautions Henan fast boiler's 1500 kg hr type steam boiler Xiao Bian told you about the operation of steam boilers and pressure fire precautions and stainless steel high temperature magnetic pump structural characteristics 1. pressure steam boiler fire steps of (1) to reduce boiler load, according to the length of time of shutdown, the seam thicker, the thickness is generally not more than 200 mm, suitable to accelerate the speed of the grate. (2) to the slag is thickened seam about 1 mm from the stop grate rotation, the drum is stopped, the operation of the induced draft fan, blowing off a small segment of the regulating plate stopper and dampers qs, relying on natural ventilation to maintain coal the lean-burn, the sewage, boiler water level will rise to the maximum allowable level. If the fire burn coal gate, grate can be switched on again, the coal-fired back, a distance. (3) the recovery boiler needs to run, as long as the opening lead, a blower, to adjust the smoke, and the wind baffle plenum segment adjusting the opening degree of the shutter, the adjustment of combustion steam boiler seam thickness to be normal, start grate, can be restored run. 2. Note the use of a steam boiler (1) before starting Check power supply voltage, there are unusual circumstances water, close the drain valve opens the water supply valve, check whether the pump stuck, stuck if the pump, remove the fan cover, rotation of the motor shaft to the flexible state to boot. (2) When the steam boiler maintenance or replacement of parts, turn off the power to avoid live work dangerous. (3) electronic control box, pump motors and other parts should avoid damp water to prevent burning boiler should pay attention to keep clean. (4) steam boilers in accordance with quality requirements, when using the apparatus sure to install a water softener, the water softener is not used because the boiler may cause fouling, may cause serious squib, shortening the life of the boiler. (5) Please note that when using sewage. And at least once a day with a discharge pressure of between 0.1MPa to 0.15MPa discharge may be prevented clogging of pipes, sewage should be properly connected, to guard against burns. Stainless steel high temperature magnetic pump structural features: a sliding bearing magnetic pump sliding bearing materials impregnated graphite, PTFE and engineering ceramics. Because of engineering ceramics has good heat resistance, corrosion resistance, abrasion performance, so the sliding bearing magnetic pump more use of engineering ceramics production. Because of engineering ceramics are brittle and expansion coefficient, so the bearing clearance is not too small, so as not to hold the shaft accident. Since the magnetic pump in order to lubricate sliding bearing medium conveyed, it should be used depending on the medium and conditions, making use of different materials bearing. 2. Cooling lubricating fluid flow control pump operation must be flush cooling internal friction annulus region between the sliding bearing and the magnetic rotor and the containment shell with a small amount of liquid. Coolant flow rate is typically 2-3% of the design flow of the pump, the annulus area between the inner magnetic rotor of the eddy current generated spacer bush high heat. When enough cooling lubricant or flushing holes poor, clogging, the medium will result in a temperature above the operating temperature of the permanent magnet, the inner magnetic rotor gradually loses its magnetism, the magnetic force actuator failure. When the medium is water or water-based liquid, the temperature rise can be maintained in the annulus region of 3-5 deg.] C; or when the medium is a hydrocarbon oil, allows the annulus region of the temperature was maintained at 5-8 ℃. Henan is committed to fast boiler steam boiler manufacturing, product quality, reasonable prices and widespread industry praise, if you have any needs, please contact us!

Steam boiler steam separator device works in the overall design of the 1500 kg hr type steam boiler, steam separator device is essential, rapid separation of water saturated steam is to improve the steam quality to ensure that an important part of the normal operation of the boiler. Fuel gas boiler is not only fuel but also refers to the gas boiler. Previously no such dual-fuel boiler, burner because either fuel or gas, no dual fuel burners. With the rapid development of the world energy equipment, some European countries begin production and sales of fuel gas burner, dual fuel burner and boiler combination of organic birth of a new breed of boiler - fuel gas-fired boiler. Biomass boiler is a kind of boiler to biomass energy as a boiler fuel called biomass boilers, steam boilers into biomass, biomass hot water boiler, biomass stove, biomass thermal oil heaters, vertical raw biomass boilers, biomass boilers and other horizontal. Convenient to meet customer needs. Then, the authors will guide you to understand the working principles of steam and water separation device on the steam boiler. First, to avoid increasing the local load between the evaporation surface and the vapor space drum boiler, the steam is uniformly by water extraction. Second, it can effectively weaken the kinetic energy soda mixture into the tank, reducing its impact on the water. Third, in order to take advantage of inertia, and centrifugal separation, the mixture having a flow path soda rapidly changing, keeping in mind the shunt separation of water, to avoid being carried steam again. Finally, there is a large surface area, in order to adhere more water droplets. At the moment, a lot of steam separator type, according to the principle of the separation can be divided into natural and mechanical separation. The principle is to use natural separation of steam and water and the density difference between the force of gravity. Mechanical separation principle relies on inertial force, centrifugal force and adhesion. Water separation apparatus is often installed in a steam boiler and used underwater plate, baffle, plate uniformity, manifold, volute separator, corrugated sheet and steel mesh separators.

Free Chat

About Us

Contact Us