1Ton Natural Gas Steam Boiler

1Ton Natural Gas Steam Boiler

50, when arranged inside the boiler room to note a safety distance, the front end of the boiler ready spacing of not less than 2/3 of the length of the furnace, and not less than 2 m; vertical boiler can be shortened; bulk boiler is not less than 4 m and does not affect the blast furnace operation and maintenance. 2, the boiler side and rear channel spacing of not less than 0.8 m, and should meet the operational and maintenance (such as replacement tube bundle cleaning, stirring the fire, etc.) requirements. 3, the top horizontal boiler headroom not less than 2 m; vertical boiler top clearance height to facilitate the operation and maintenance; headroom boiler room the other channels, should not be less than 2 meters, when the passage of time and no need to operate its headroom height of 0.7 meters. 4, the boiler room is provided for two or more boilers, the boiler the distance between adjacent not less than 1 to 1.5 times the cylinder diameter of the boiler. 5, the boiler room is generally preferred fireman operation chamber provided, on the total rated greater than or equal evaporation 4t / h 1ton steam boiler (heating or hot water boiler is equal to or greater than 2.8MW) must be provided stoker operating room. Electric boiler tank may be provided in front of the boiler, and to ensure the art to fireman facing boiler water gauge, pressure gauge and other instruments during operation. 6, to the total rated evaporation 2t / h fuel gas boiler room to be provided or water spray foam fire extinguisher system, should outdoor outdoor fire hydrant, other fire-fighting equipment should also have the boiler room. 7, the fuel in the boiler room daily oil tank, the oil pump is generally not located in the boiler room, between daily oil tank, the oil pump between the application of the fire resistance of greater than 2.00h wall, the fire resistance of greater than 1.50h floor spaced from the other parts. Daily fuel tank between the boiler room and the door between the oil pump should be able to self-closing fire doors Class A, and let the oil block measures. Household upper tank return pipe to be provided, should be greater than the oil return pipe back to the oil pump. 8, an oil tank and all piping must have a reliable electrostatic grounding, the grounding resistance should not exceed 30 ohms. 9, gas boiler room boiler design should also comply with the relevant safety requirements of gas boiler room.

Boiler Association party leaders to come soon Group: innovation and development has won high praise, Secretary General of China Association for boiler water treatment boiler and arrogance Ling Wang, Assistant Secretary Guo Hua, chief engineer Tongyou Wu and his party three people come fast Boiler Group inspections visits, Luhai Gang president accompanied by full enthusiasm.

Note matters including gas boiler gas water boiler, gas hot water boiler, gas 1ton steam boiler operation gas boiler, gas hot water boiler which is also known as gas heating boilers and gas boilers bath, as the name suggests refers to the gas boiler fuel gas boilers, gas boilers and oil-fired boiler, electric boiler compared to the most economical, most people have opted for a gas boiler as steam, heating, boiler equipment for bathing. Note that the operation of the gas boiler gas boiler valve matter is very common to use an apparatus of the plant, under normal circumstances the handle, thorium clockwise rotation of the handwheel is turned off a predetermined direction, the rotation is defined as counterclockwise opening direction. But before the operation should focus on some check valve opening and closing flag after the operation. The following gas boiler manufacturers of small series simply to introduce the next gas boiler ajar fast opening valve operation Note: gas boiler slowly open the valve to open, slightly open after the quick opening valve, preheat the pipe and then fully open. For better results the sewage, can switch several quick open valve. After discharge, turn off the quick opening valve, then slowly open the valve is closed, and finally open about fast opening valve between two valves to put water in the net.

How much gas 1ton steam boiler power and water consumption about? One ton of steam coal boiler is about 85 kilograms, a ton of steam consumption of natural gas is about 80 square. I do not know the local fuel prices. Meanwhile, steam boiler tons of gas consumption to about 7 degrees, and tons of gas boiler steam power was insufficient. This is the cost of consumption, you can according to the local point, calculate the cost of coal. Other aspects of superior gas or gas, such as environmental protection, operating environment, repair and maintenance.

Free Chat

About Us

Contact Us