3Th Oil Fired Steam Boiler

3Th Oil Fired Steam Boiler

6 tons of natural gas 3th fired steam boiler steam boiler price of 6 tons of natural gas generally used in areas such as factories and large workshops, with the general ordinary civilian-type heating or hot water is not such a large tonnage, 6 tons of natural gas steam boiler where prices Best prices? Here Xiaobian to recommend a fast-party manufacturer Henan plant, Henan party fast as a professional production of gas-fired plant has a history of nearly a hundred years, the production of natural gas steam boilers are divided into different types based on price, respectively, : ZWNS0.7-85 / 60-Y, Q, ZWNS1.4-85 / 60-Y, Q, ZWNS3.5-85 / 60-Y, Q, ZWNS7-85 / 60-Y, Q, etc., wherein the sales to the best number six tons of natural gas steam boilers, and why this fast Henan party product sales so good? The main reason is: 1, the combustion chamber is increased, so that the combustion more fully and more effective. 2, threaded smoke tube structure, the effect of enhancing heat transfer, avoiding waste 3, designed to over-temperature, over-pressure, water, and other automatic flame protection, enhanced safety factor 4, Italy imported burner, automatic control good results. 5, the barrel is made of high heat resistant material, including oil and gas is the external heat, the overall effect is very good insulation, but also easy to place very small. 6, belongs to the boiler quick, easy installation, simple operation. It is because of these advantages Henan party fast six tons of natural gas sales gas boiler is so good! Contact online engineers we will provide more detailed information and quotes for you this month in advance of the call can also enjoy price concessions.

Temperature protection device during the fuel 3th fired steam boiler over temperature to regulate protective effect of temperature protection is an important procedure fuel steam boiler safe operation is particularly important for the regulation and protection of the boiler temperature of the fuel vapor; at the same time to regulate in the fuel steam boiler overtemperature Protective effects. Conventional boiler temperature protection means is a bimetallic temperature controller. Flame protection: prevent explosion of the furnace, steam boiler fuel flame protection means must be provided, is a function of combustion (including ignition, combustion or misfires when halfway off, typically within five seconds reignition monitoring the furnace, a second the run off into the oil (gas) solenoid valve, and turns on and audible alarm signal, when the blower continues to operate, the residual gas was purged of combustible furnace, after 20 to 30 seconds purge, automatically cut off and various auxiliary blowers supply the boiler operation stops. role is to monitor the flame signal the presence of a flame or an interrupt control apparatus mainly using a photomultiplier tube, a photovoltaic cell and photosensitive resistance, they have an infrared type or ultraviolet type a photoelectric conversion element, the working principle of the light converted to the corresponding strength of the radiation strength of current and the linear output state, sometimes weak induction current, through amplification, in order to have an effect on the controller.

Blue Sky Battle horn started, our country constantly walking on the green road. Reduce atmospheric emissions of nitrogen oxides, improve air quality, but also the people a blue sky, the industry has invested in the construction of environmental protection go, Guizhou Baiyun Quan Lake Hotel is no exception. As we all know, fast boiler R & D in the field of clean fuel boiler never stopped, through market research and screening, Guizhou Baiyun Quan Lake Hotel in October 2017 signed a low-nitrogen Thalia T5 series vacuum hot water and fast boiler boiler for hot water supply and heating the hotel.

1: Steam boiler steam pressure the higher the better selection pressure, depending on the user's requirements. Vapor pressure, safety pressure member Advantageously, the energy consumption is low; but the steam will be relatively worse quality, low enthalpy, humidity, may be difficult to meet the disinfection, sterilization, culture, heating and power needs. And the high vapor pressure, energy consumption is high, the corresponding steam equipment, piping and valves the pressure is high, the maintenance requirements are also more, the production of steam, the heat transfer process, a large leakage loss. Meanwhile, high-pressure steam as the steam pressure is increased to carry the increased salinity, so salinity these waterwall tubes, pipe tobacco, and other drum heating surface fouling, overheating, foaming, clogging even increase the possibility of squib. Salt steam to steam turbine flow area will decrease, reducing the efficiency and seriously affect the heat transfer. Thus, fireman must operate in accordance with operation of the steam pressure, the steam pressure fluctuations generally allows a value between 0.05 ~ 0.15MPa.

2: the higher the boiler water level was considered safe water level is higher, the boiler water is not easy, security is also guaranteed. In fact, this is a misconception, the water level is too high, steam and humidity increase, poor steam quality, steam equipment will harm and production results. Industrial boilers, a moisture vapor sterilization or incubation with a large amount of steam also increased salt, or culture for a long time ranging from sterilization, steam consumption increase, ineffective, decreased production culture; weight is not reached the purpose of disinfection or cultured biological products contaminated scrap, even pipes, water hammer occurs apparatus. For utility boilers, steam moisture capacity, the steam turbine last stage blades will be erosion, there may appear Priming pot, water shock severe enough to cause harm equipment and personal safety. Thus, the pot water level should be maintained within a fluctuation range of ± 50mm well.

3: Some people think the better fuel plus fuel plus the more productive the greater the amount of steam. Little do they know too much fuel into the furnace, the effect will be counterproductive. When a certain amount of air and the excess amount of fuel, the furnace will produce a large amount of incomplete combustion, resulting in energy waste. People often see the dark furnace flame, weakness, and black smoke chimney, mostly for this reason. In severe cases, there will be fire pulverized coal, oil furnace secondary combustion occurs, burst pipes until shutdown. Therefore, the ratio of fuel and air volume should be adjusted appropriately, typically by looking at the fire, smoke color look, see table indicates the amount of oxygen determined. When the flame in the furnace as a bright yellow, pale gray smoke chimney to take, stable vapor pressure, wind coal showed appropriate ratio, good combustion.

4: Dial stirring the fire, the better the fire is commonly used in industrial boilers manual method. By stirring the fire, can be eliminated crater, reduction furnace from the fire and the fire bed smooth, homogeneous combustion, strong. But too much stirring the fire, but will reduce the overall thermal efficiency; this is because when stirring the fire, a lot of cold air into the furnace, reducing the average temperature of the furnace section of the flame. At the same time, increase the heat losses, an increase in the number of black smoke chimney, pollution of the environment. In addition, when stirring the fire, the staff is also susceptible to flame radiation, burns, fire-resistant layer is also susceptible to dial hearth fire damaged tools, increased furnace building maintenance workload. Therefore, the fire should be allocated as needed, to minimize the appropriate dial.

5: the bigger the better furnace pressure and furnace pressure is reflected in one of the boiler combustion conditions is normal or not an important parameter. Operating the boiler furnace negative pressure should be maintained between 10 ~ 20Pa, too great a negative pressure results in: increased leakage furnace, heat losses increase; wind increased electrical energy consumption; fly ash increased the wear along the heating surface; reduced the furnace heat of combustion efficiency. Most gas-fired boiler designed to run slightly positive pressure to increase the combustion rate. Operation, the furnace pressure becomes positive, even increasing the wind is still difficult to maintain the chamber negative pressure, said system failure or the wind furnace wall tubes, superheaters and other soft drinks leakage; fire furnace, the furnace pressure is first reflected table violent swing to the negative direction flung head. Therefore, the furnace pressure must be run according to the provisions, or should pinpoint the cause.

6: sewage longer the better spoken here regularly refers only to the sewage discharge rather than continuous blowdown. Periodic sewage mainly refers to the existence of negative bottom of the boiler slag, dirt and corrosion products, reduce furnace tube fouling, prevent clogging and reduce the salt content of the water boiler, heat transfer enhancement effect. One would think that the longer the discharge time, impurities will be discharged bottom of the pot the more, the better sewage, it is not. Sewage long time, a waste of a lot of heat, affect heating steam pressure; two pairs of boiler water circulation unfavorable, water wall tube burst will occur in severe cases. Thus, the sewage must be periodically according to "ground discharge, the discharge less uniform row" principle, provided hand operation. General Provisions at least once every eight hours of sewage, sewage each time shall not exceed 30s, overtime is strictly prohibited.

Free Chat

About Us

Contact Us