5 Mw Gas Boiler In Thailand

5 Mw Gas Boiler In Thailand

Boiler from coal to gas is to use the original coal-fired 5 mw boiler in thailand demolition transformation, Burning natural gas. Compared to gas-fired boiler coal-fired boiler, the first environmental protection, the second can. Carrying coal to gas in the process, you will find that there are different gas-fired boilers, in addition to ordinary gas boiler, as well as more energy-efficient condensing gas boiler. Ordinary gas boiler is outdated, on energy saving can also have a higher standard. Then condensing gas boilers and gas boilers ordinary What are the differences?

Such as hotel Home Hotel Group is one of the three major brands, in 300 cities in the country has nearly 2,000 hotels. Home Inns has won China Golden Pillow Award for Best Chinese economy hotel chain brand award, in 2014, Home Inns brand value of $ 420 million of selected China's top 100 brands. April 4, 2016, BTG hotel groups such as the privatization of the hotel purchase transaction has been completed delivery. In mid-2016, as a Beijing hotel with our preliminary communication, the urgent need two 5 mw boiler in thailands work of heating and hot water supply. I related technical engineers and recommend it to calculate the number and size of the boiler on the hotel room as hotel Willy sharp V6-99 two models.

Gas-fired steam 5 mw boiler in thailand and gas steam boiler at any time there is any good compared to the country more and more attention to environmental protection, gas steam boiler has been a great blow, and relatively gas steam boiler by many users of all ages, in recent years, the country also strongly promote the use of gas-fired boiler, gas steam boiler then compared with the gas steam boiler what good is it? And today we work together to explore. Gas-fired steam boiler steam boiler and gas each accounted for half of the market, showing potential rival, but in the long run, gas steam boiler will obviously be the only dominant market. Do not believe, look! 1. Purchase costs: gas boiler is evident in the technical and auxiliary facilities are far ahead of the gas boiler, and it is equipped with a special gas burner. 1 steam boiler tonnage, for example, the price of gas than the gas boiler boiler on high about 30%. 2. Construction costs: The costs mainly from the boiler room. Because the corresponding auxiliary equipment more gas steam boiler, the boiler room in the building have a little more money. The gas boiler auxiliary facilities require little or automatic control and operation, and automatic alarm and automatic protection, not only save building costs, but also safe and reliable; Also connected to the gas pipeline, the burner will automatically supply gas can effectively save costs staff. The gas-fired boilers because of the need of coal on the program, so it needs some staff payroll. 3. Fuel cost: around this by looking at the actual specific fuel price can be clearly seen. The fact is that the amount of gas than the gas burned per hour for much more. 4. environmental costs: in the need to protect the environment, review the current gas boiler more strict. The gas steam boiler due to the operation of the economy, environmental protection and energy saving, as well as government policy to encourage more and more widely used.

Temperature protection device during the fuel steam 5 mw boiler in thailand over temperature to regulate protective effect of temperature protection is an important procedure fuel steam boiler safe operation is particularly important for the regulation and protection of the boiler temperature of the fuel vapor; at the same time to regulate in the fuel steam boiler overtemperature Protective effects. Conventional boiler temperature protection means is a bimetallic temperature controller. Flame protection: prevent explosion of the furnace, steam boiler fuel flame protection means must be provided, is a function of combustion (including ignition, combustion or misfires when halfway off, typically within five seconds reignition monitoring the furnace, a second the run off into the oil (gas) solenoid valve, and turns on and audible alarm signal, when the blower continues to operate, the residual gas was purged of combustible furnace, after 20 to 30 seconds purge, automatically cut off and various auxiliary blowers supply the boiler operation stops. role is to monitor the flame signal the presence of a flame or an interrupt control apparatus mainly using a photomultiplier tube, a photovoltaic cell and photosensitive resistance, they have an infrared type or ultraviolet type a photoelectric conversion element, the working principle of the light converted to the corresponding strength of the radiation strength of current and the linear output state, sometimes weak induction current, through amplification, in order to have an effect on the controller.

Free Chat

About Us

Contact Us