5000Kg Boiler Suppliers

5000Kg Boiler Suppliers

Boiler furnace pressure too much, what harm: 5000kg boiler suppliers furnace pressure is too large, indicating that the induced draft fan suction force is too large. At this time, the air flow has shifted to the boiler upturned, center of the flame, furnace exit gas temperature rise, temperature rise caused by the steam superheater or slagging. Upturned gas flow, the flame travels shortened, resulting in incomplete combustion.

After use throughout the winter, the Central Conservatory of Music give us feedback, six V6-99 fully meet the heating needs of the school. And 5000kg boiler suppliers fuel and water requirements are not high, urban water and low-pressure natural gas combustion can operate. The most important point is that nitrogen oxide emissions are very low and very happy to recommend it to others to do the brother of boiler units. --customer feedback

Hotels fired 5000kg boiler suppliers Introduction: Introduction: The hotel is heated by oil-fired boiler burners, fuel atomization effect, fuel combustion, can not see the chimney smoke, so the green fuel boilers, energy efficient. After spraying fuel through the burner into the furnace in the atomized droplets, and easily mixed with air and the rapid combustion heat flash. Compared with coal-fired boiler with the same capacity, and parameters, which furnace volume heat intensity may be increased about twice. Features: 1, automatic water boilers, water full automatic stop, and the user can set the start, shutdown time, the setup is complete, no special duty, and because energy saving, save, save money. 2, the boiler dual fuel burners, both the fuel, but also gas, a combustion burner automatic stop controller in accordance with the instruction, a separate control box has a number of security, performance, security and stability, low maintenance. 3, the inner fire tube inserted spoiler retardant, smoke slow speed, to strengthen the heat exchanger, combustion heat is conducted to a large extent in water, the discharged flue gas temperature is low smoke chamber, reducing heat loss and save fuel. 4, according to atmospheric boiler design, boiler in a non-pressure state, there is no safety hazard. 5, centrifugal multi-layer insulation glass wool, steel for packaging famous white color, heat loss, anti-rust appearance. 6, gas hot water boiler fuel is widely used in homes, villas, hospitals, schools, hotels, restaurants, fitness center, bath center and other enterprises.

Use steam 5000kg boiler suppliers pressure gauge should pay attention to the following items: 1, rated steam pressure is less than 2.45MPa steam boiler, pressure gauge accuracy must not be both 2. 5; Rated steam pressure large or equal to 2.45MPa boiler, pressure must not be less than 1. 5 class. The dial diameter of the pressure gauge shall not be less than 100 mm to ensure that the operator can see the surface pressure indication clearly. 2. A red line should be drawn on the pressure dial of the steam boiler pressure gauge, indicating the maximum allowable working pressure. 3. Steam boiler pressure gauges should be installed in places that are easy to observe and rinse, and should be protected from the shadows of high temperatures, freezes and vibrations Ring. 4, steam boiler pressure gauge should be checked at least once every six months, after calibration should be sealed. 5, steam boiler pressure gauge connection pipe should not leak, steam leakage phenomenon, otherwise will reduce the pressure indicator value. 6. The range of the steam boiler pressure gauge shall be adapted to the working pressure of the measured components, usually 1.5 times of the working pressure, preferably 2 times of the working pressure. Steam boiler does not have a pressure gauge, the pressure gauge is damaged or the installation of the pressure gauge does not meet the requirements, steam boiler pressure gauge should be stopped when one of the following: 1, broken surface glass or dial calibration unclear; 2, no lead seal, lead seal damage or Beyond the calibration period; 3, when there is no pressure, the pressure gauge pointer of the finite pin cannot be restored to the limit pin, and the data of the infinite position gauge pointer deviating from the zero position exceeds the pressure coat allowed? Poor; 4, gas leak or pointer jump in the meter; 5, other defects that affect the accuracy of the gauge.

Free Chat

About Us

Contact Us