5000Kg H Gas Fired Steam Boiler

5000Kg H Gas Fired Steam Boiler

The following are the nine safety devices gas 5000kg h fired steam boiler. 1, water level monitoring: the original four water level is detected on the basis of a new fifth level detection, water level in cooperation with electronic detection devices, more comprehensive monitoring of boiler water level. 2, set the time: the user can set the starting time required to stop the boiler, free combination, convenient and flexible. 3, leakage protection: when the control system detects leakage electric heating elements, will automatically cut off power to prevent leakage fault occurs. 4, water protection: When the boiler water promptly cut off the gas burner control circuit to prevent the occurrence of dry damage the burner, while the controller sends water alarm indication. 5, power anomalies protection: Upon detection of a power failure, the boiler will stop running immediately. 6, the interlock overpressure protection: When the boiler pressure exceeds the user set value, the burner operation is prohibited and the alarm. 7, pressure controller, water level alarm, safety valve, low water level alarm and other multiple security. 8, a complete gas valve and protection system: providing a gas valve and accessories from whole filter, regulator and solenoid valve, ensuring safety gas. 9, real-time monitoring of flue gas: exhaust gas temperature of the boiler can be automatically monitored more easily grasp the combustion boiler.

The main components of the boiler: boiler lot of people know, but do not always understand the boiler, even customers who have purchased the boiler is not very understanding of what are the component parts of the boiler. Today to look at a detailed analysis of boiler components which mainly consists of: 1, drum. Its role is to collection, storage, and supplementary steam feedwater purification. In water-tube boilers usually 1 to drum 2, the drum is called a steam drum (drum), referred to below water or mud drum drum. The inner drum has a uniform distribution of the feedwater tank, and the water separation means the continuous blowdown apparatus. Internal boiler drum water tube assembly and a separator and the like. The outer drum containing the main steam valve, the sub-steam valve, safety valve, air valve, water level gauge, sewage connection pipe and pressure gauges. One end of the head or top of the drum was Manhole. One end of the drum head with the open manhole bottom with periodic discharge means. In many riser and downcomer (bundle) connected to form the entire structure of the elastic member between the upper and lower drum. 2, water wall heating surface. It is disposed around the furnace radiation heating surface. Boiler tube made of φ51 × 3 ~ φ63.5 × 3.5mm in industrial boilers generally used rust, while the main heating surface of the water tube boiler. Radiation heating surface absorption of radiant heat and flame shield the furnace wall, and thus play a protective role in the furnace wall; the same time, as more endothermic, the furnace temperature can be reduced, as well as to prevent burning effect coking coal seam. 3, header. It is a collection of tubes arranged in the main element is coupled, and a dispensing action of water drawn, its location has upper header and a lower header or inlet header and the outlet header bin of. A header welded seamless steel pipe is generally greater diameter and two end caps. In recent years, some manufacturers shut spinning tube ends, substituted welded end cap, a more rational structure. 4, the convection heating surface tubes. Convection convection bank known as the drain pipe, located between the upper and lower drum, generally by a boiler φ51 × 3mm steel composition, the main heating surface of the water tube boiler. In order to sufficiently absorb heat, convection bank usually intermediate, separator trap wall consisting of a flue or turns back and forth, increasing the flow of flue gas, and smoke at high speed across tube bundles. 5, the pyrotechnic heating surface tubes. Smoke tube heating surface is the main fire tube smoke-tube boiler and a combination boilers, its role is as high temperature flue gas generated from the combustion furnace flows through the inner tube, the outer pot of water continuously on the heating tube, it gradually becomes steam (or hot water). Smoke tube is typically mounted pot shell, fixed to both ends connected to the tube plate by welding or expansion. Because of its limited number of installations of the boiler shell, plus content of the tube is easy to plug fouling, easy outer tube fouling, it is not practical for large boilers. 6, the superheater. Economizer and air preheater, which belong convection heating surface. Superheater convection superheater addition, there are radiation superheater, economizer and a preheater rest are mounted boiler backpass. Their role in the main exhaust gas temperature is further reduced, improving the thermal efficiency of the boiler.

Steam boiler pressure gauge should pay attention to matters 1. The rated steam pressure less than 2.45MPa 5000kg h fired steam boilers, pressure gauge accuracy of not less than 2.5; equal to the rated boiler steam pressure 2.45MPa, the pressure shall not be less than 1.5. Electric heating boiler and the boiler is mainly composed of electric control box and control system. Its characteristics are environmentally friendly, clean, no pollution, no noise, automatic, with limited energy and reduce prices significantly, as a new boiler electric heating boiler equipment increasingly being recognized. Electric heating the core member is electrically heated boiler, directly determines the life of the boiler, to select a non-metallic electrical heating tube (such as a ceramic heating pipe), because it is resistant to the load, a long life, and a water separation structure, the boiler Wing no leakage. There are heating and hot water boiler bath for two purposes. Hot water boiler by circulating hot water circulation pump hot water holding tank, the tank hot water heating cycle can be achieved bath object; hot water boiler by circulating hot water circulation pump heating conduit, through the heat sink (radiator) people can achieve heating requirements; hot water boiler and hot water circulating pump with heat exchanger can be achieved bathing and heating dual function. Dial gauge diameter of not less than 100 mm, to ensure that the operator can clearly see the surface pressure indication. 2. On the dial gauge steam boiler should draw a red line to indicate the maximum allowable working pressure. 3. The steam boiler pressure gauge should be installed in place to facilitate the observation and purged, and should prevent high temperature, vibration and icing. 4. The steam boiler pressure gauge should be checked at least once every six months, to be sealed lead-sealed after calibration. 5. The steam boiler gauge connection tube not leak water and steam, otherwise it will reduce the pressure instruction value. 6. A steam boiler pressure gauge measuring range should be compatible with the operating pressure of the device under test, the working pressure is generally 1.53 times, preferably 2 times the working pressure. Steam boiler no pressure gauge, pressure gauge or pressure gauge damage does not meet the requirements. When the steam boiler pressure gauge of the following circumstances, should stop using: 1. The surface of the glass or the dial pins; Lead seal, lead seal is broken or exceeds the calibration period; when no pressure gauge pointer position is limited to the limit staple nail can not be restored, and the rank unlimited gauge pointer movement from zero data is out of range pressure layer. Poor; leak or pointer jitter in the meter; other defects affect the accuracy of the pressure gauge. The use of the accumulator: the accumulator for a hydraulic system of the machine intermittently. It may be a low speed motion or intermittent motion of the actuator, the oil reservoir of the hydraulic pump, when rapid movement of the actuator requires a large flow rate, as an auxiliary energy supply to the system together with the hydraulic pump, enabling the pump and the entire hydraulic system miniaturization, to achieve energy saving. Hydraulic shock absorber valve and the opening and closing of rapid mutation load, the system generates a pressure shock, loved one causes vibration and noise and even damage the machine. The accumulator can relax and absorb the impact pressure of the liquid. Accumulators absorb and reduce the pressure pulsation flow pulsation and various hydraulic pumps, thus reducing noise and vibration system. The function of the gas spring having a damper, the vibration can be used to walk between the car body and the wheel and other mechanical absorption. The accumulator may be balance gravity vertical actuator (hydraulic cylinder) and the potential energy absorbing load drop into hydraulic energy storage, while producing speed resistance. When the rising vertical actuator, the accumulator absorbs energy of the original release, and together with the oil pump to the hydraulic cylinders, so as to achieve balance and energy.

Recently, Shaoxing, Zhejiang Province, the municipal government issued "on the issuance of Shaoxing new coastal air quality standards carry special action program" (the "Notice"). "Notification" is mentioned: a ban on new biomass boilers, nine companies continued to promote the transformation of low-nitrogen gas boiler.

4. The built-up area to carry out bulk coal campaigns to strengthen the use of bulk coal production and life behavior of businesses and residents a comprehensive investigation and persuasion, to ban briquette production and sales, and increase legal coal quality supervision, strict penalties for substandard coal burning behavior.

2. carry out an intensive investigation, the establishment of various types of industrial furnaces inventory management, development of industrial furnaces depth remediation, complete elimination of the task assigned by the city. Strictly implement the relevant emissions regulations, can not reach the relevant requirements, the implementation of cut-off regulation.

3. Conduct brick kiln depth remediation, strict implementation of emission standards, enhance on-site inspection of law enforcement, monitoring, focus on examination of the "three simultaneous" implementation and pollutant emissions, on-site monitoring of the discharge port sulfur dioxide, nitrogen oxides, particulate matter and other pollutants .

Free Chat

About Us

Contact Us