8 Ton Gas Steam Condensing Boiler

8 Ton Gas Steam Condensing Boiler

Wuhan Yu Dahua Group Co., Ltd. is a cotton based, weaving, knitting and textile car decoration installation in one of the cross-industry, diversified and comprehensive export-oriented enterprise groups. 2017, the Group expanded production scale textile processing, the number of new production lines, the Group's original steam 8 ton steam condensing boiler can not meet the growing demand of orders in urgent need of a new steam boiler purchase. When selecting vendors steam boiler, the boiler output device side fast sustainable high quality steam attracted, decided to cooperate with the fast boiler. Fast art by side to the user site needs analysis, to provide two integrally condensing gas steam boiler (WNS4-1.25-Y.Q).

The inlet speed of gas-fired hot-water 8 ton steam condensing boiler before start-up should not be too fast, usually no less than 4 hours in winter, and 2-3 hours in other seasons, especially in the initial stage of water intake. The inlet temperature of a gas-fired hot water boiler is generally 50 °C, so the difference between the feed water temperature and the steam wall temperature in the drum is less than 40 °C. For gas-fired hot water boiler, the inlet water temperature can be equal to that of steam drum wall without complete cooling, otherwise the inlet water speed should be slowed down. When feed water enters the drum, it always first touches the lower part of the drum. If the difference between the feed water temperature and the drum wall temperature is too Large, the inlet speed is fast, and the upper and lower walls of the drum, the inner and outer walls will have a large expansion. Bad, on the drum caused a lot of additional stress, resulting in drum deformation, serious cracking. Due to the thickness and slow expansion of the drum wall, the tube wall connected to the drum wall is thinner and expands faster. If the inlet temperature of the gas-fired hot water boiler is too high or the inlet speed is too fast, the expansion will be uneven, the welded joint will appear cracks and the gas-fired hot water boiler will be damaged. The inner diameter of the decompression tube is usually φ 7~13mm (water and steam), and its length should not be too long (< 60m). Straightness of pressure pipe If the diameter is too small and the length is too long, it will affect the dynamic transmission of pressure measurement and increase the dynamic error. The inner diameter is too large to be easily maintained and installed. Pressure pipes should not be placed in the horizontal part to prevent the accumulation of bubbles (when measuring liquids) and water columns (when measuring gases). The pressure tap shall be perpendicular to the flow of the medium. Pressure faucet must not have chamfer, flange and burr. When measuring the hydraulic pressure of an electrically heated steam boiler, the pressure outlet should be removed from the lower part of the pipe to prevent the gas in the liquid from entering the pressure guide pipe; When measuring the gas pressure, remove the pressure splice from the upper part of the pipe to prevent dust and dust in the gas The droplets enter the ignition line. The installation site of the electric heating steam boiler pressure gauge (pressure transmitter) should meet the environmental conditions (temperature, humidity, vibration, etc.) used by the instrument, and should be easy to observe, repair and ensure safety. Insulation should be laid on pressure pipes in high temperature media to avoid burning during flushing. Pressure lines are equipped with needle valves (for cutting off pressure in the event of pressure line failures during operation), auxiliary needle valves (for use with instruments, stopping, replacement), condensing coils and elbows (isolation elastic elements from high-temperature media), Easy to install sealing gaskets) as well as sewage valves and sewers. For special pressure measurements, it's still pressing. Install discharge valve, isolation room and so on in the force pipe.

Classification and distinction and design a gas 8 ton steam condensing boiler, gas boiler gas boiler classified in accordance with the fuel can be divided into natural gas boilers, boiler city gas, coke oven gas boiler, liquefied petroleum gas boilers and gas boilers; according to the function can be divided into gas boiler water , gas hot water boiler (gas heating boiler comprising a boiler and bath gas), gas steam boiler and the like; can be divided according to the structure of vertical gas boiler, gas boiler horizontal; in accordance with the process can be divided into a single flue gas boiler and tris backhaul backhaul gas-fired boiler. Second, the difference between fuel oil-fired boiler fuel boilers and gas boilers is fuel (such as diesel, oil, kerosene, etc.), fuel gas-fired boiler to gas (such as natural gas, city gas, biogas as well as liquefied petroleum gas, etc.), depending on the boiler What fuel burning device called a burner, boiler gas burner configuration called gas-fired boiler, oil boiler burner configuration called oil-fired boiler, oil-fired boiler and gas boiler difference is that what fuel burners. Third, the design of the boiler furnace by the gas boiler structural design pressure, provided through the top of the large pores, the boiler operates at atmospheric pressure, away from the danger of explosion; boiler furnace using computer simulation to optimize the design, the size of the boiler is fully optimized, so that coordination and beautiful form. Vertical-mounted boiler combustion at the burner, combustion of the fuel within the positive pressure furnace, baffle interposed smoke tube, slow smoke evacuation rate, to strengthen the heat exchanger, the heat furnace to ensure maximize fuel combustion water, improving the thermal efficiency of the boiler; horizontal wet back boiler full three pass structure, the length of the flue gas flow, reducing exhaust gas temperature, the whole corrugated furnace provided, so that the flame produced a strong turbulence to improve the heat transfer coefficient strength, and effectively It is prevented due to thermal expansion and contraction of metal results in a reduction of the life of the device; smoke tubes of large diameter and large pore bridge the gap, the boiler at equal time scale coating thin and easy to clean.

Tail gas 8 ton steam condensing boiler heating surface, promote energy conservation, steam boiler, make full use of surplus gas, iron and steel ring can be part of the No. 2 boiler recently implemented gas utilization upgrading the premise of low temperature corrosion does not occur. The transformation of the original two No. 2 Power Station Boiler 220 t / h circulating fluidized bed boiler, the transformation of 200 tons / hour gas-fired boiler. To reduce the cost, Shaoguan Iron & Steel ring portion can be modified in the original boiler equipment, removal coal system, discharging systems, dust removal systems, fuel systems; Lee used equipment including the original boiler water wall, drum, steel frame, platform escalators, tail shaft convection heating surface, steam systems, water systems and some electrical, instrumentation and other facilities, while adding the blast furnace, a coke oven gas in each system, the new blast furnace, coke oven gas mixing burner 4, the combustion of blast furnace gas device 4, a low-low pressure economizer, the boiler flue gas boiler guaranteed emissions compliance and four 10 kV high-pressure fan, part of the electrical and gas drainage, tail heating surface is not provided at a low temperature corrosion occurs meter facilities. No. 2 boiler after the upgrade, to ensure the boiler flue gas emissions standards and low temperature corrosion tail heating surface does not occur under the premise, as far as possible be able to mix more burning oven gas, surplus gas consumption, save energy and reduce environmental pollution.

Free Chat

About Us

Contact Us