Combined Heavy Oil Fired Vertical Boiler In Asia

Combined Heavy Oil Fired Vertical Boiler In Asia

Ukraine industrial construction quality, customer Ukraine's current visit to our company is very interested in industrial steam combined fired vertical boiler in asias. Our technical staff will fast one side condensing gas steam boilers, steam pipes condensing gas boilers and other star products, from performance to the advantage of his right to the customer. Natural gas is clean, easy to use and other advantages, is to use one of Ukraine accounted for a large amount of the type of energy. Fast boiler since its inception in 1998, with great concentration R & D and manufacturing of gas clean fuel boiler, has a very extensive industry experience, and to respond positively to the pace of global environmental development for the market launch of the gas boiler is not only the thermal efficiency is very high (up to more than 108%), emissions of harmful substances is very low (less than 18 nitroxides mg / m3).

PRODUCT INTRODUCTION fuel gas-fired combined fired vertical boiler in asia fuel gas-fired boilers and coal-fired steam boiler is not the same, gasoline and diesel and gas-fired burner must be poured into the fuel to the boiler furnace using a combustion chamber rather than grate facilities. Since the fuel gas-fired boiler is not easy to cause the fly ash lit, so no oil or gas boiler slag removal equipment. If mixed with air or exterminate within a certain range, it is introduced into the furnace petrochemical and gas easily the explosive. Thus, any gasoline and diesel and gas-fired boilers must be selected and automatic combustion control system. Compact boiler fuel gas, and the small boiler exhaust, drainage, control and auxiliary equipment installed at the distribution panel, and produce large and small boiler assembly. Fuel gas-fired boiler safety valve installation key point describes the installation of fuel gas-fired boiler safety valve sure to carry out in accordance with reasonable installation process, to prevent wrong and lead to risk. Fuel gas-fired boiler safety valve installation should pay attention to what matters? The following is a brief description: 1 oil-fired boiler safety valve having a lever bar to avoid self-weight and the mobile device guide body defining deviant lever, the spring valve lift handle and avoid the need for screw adjustment means random twist. 2. Rated evaporation than 0.5t / h gas boiler safety valve should be arranged at least 2, Rated evaporation gas boiler should be equal to or less than 0.5t / h, fitted with at least one safety valve. Separable economizer outlet and a steam superheater outlet valve should be installed. Sectional area of ​​the connecting pipe between the boiler safety valve 3. Fuel gas boiler can not be lower than the imported cross-sectional area of ​​the valve. If several valve mounted on each stub is directly coupled to the drum, the passage sectional area of ​​the stub is less than 1.25 times not all of the area of ​​the exhaust valve. 4. Oil and gas boiler safety valve should be mounted vertically in the height of the boiler drum and the header. Can not be mounted between the valve and the steam outlet conduit and the valve drum or header. 5. For rated steam pressure less than or equal to 3.82MPa boiler safety valve throat diameter of not less than 25 mm; the rated steam pressure is greater than 3.82MPa boiler safety valve throat diameter of not less than 20 mm. 6. Fuel gas boiler safety valve should normally be established an exhaust pipe, the exhaust pipe should be directly connected security grounds, and there is sufficient cross sectional area to ensure the smooth flow of the exhaust gas. The bottom of the valve should be equipped with an exhaust pipe connected to the drain of a safe place. Valve must not be installed in the exhaust pipe or drain pipe.

Using imported burner, automatic programmed control, automatic purge blower, electronic auto-ignition, spontaneous combustion and gas, (air) to automatically adjust the proportion of oil wind, good atomization, combustion, energy saving, have flame protection device ensures combustion safety. Under normal circumstances, the combustor output temperature of the combined fired vertical boiler in asia with the combustion flame length is automatically adjusted, the outlet temperature of the boiler reaches the set value, the burner combustion is automatically stopped, when the temperature is below the set value, the burner is automatically started. When the abnormal phenomenon of the fuel, air intake, fault lights, the output sequencer will immediately stop the fuel, burner shut down automatically.

The gas burner is configured by the five gas burner system components 1 structure, the air supply system consists of the following five system. Function into the air supply system is to a certain wind speed and amount of air to the combustion chamber, its main components are: a housing, fan motors, fan impeller, air guns fire tube, damper controller, damper baffle, a cam adjustment mechanism, diffusion plate. 2, the ignition system. The function of the ignition system ignites the mixture of air and fuel, its main components are: the ignition transformer, the ignition electrode, a high voltage electrical cable fire. A more secure electronic ignition system called ignition pulse, is widely used Zhuoyi energy saving gas combined fired vertical boiler in asia manufacturers. Which facilitate saving, can simply press a finger, and safe, does not occur due to unexpected accidents occur flame, once the stall state occurs, the control system can close the solenoid valve, off the gas passage. 3, the monitoring system. The function of the burner to ensure the safe and stable operation, the main components are flame detectors, pressure monitors, temperature monitors and the like. 4, the fuel system. Function of the fuel system is to ensure that the desired fuel burner. The fuel oil burner system are: tubing and fittings, pumps, solenoid valves, nozzles, heavy oil preheater. The gas burner mainly a filter, pressure regulator, solenoid valve, and then firing solenoid valve, the fuel valve. 5, electronic control system. Electronic control system is the command center and the focal point for the above system, the main control element is a control box, for different burner with a different programmer, common control box has: LFL series, LAL series, LOA series, LGB series the main difference is the time of each different program steps.

Free Chat

About Us

Contact Us