Delicate Processing Oil Boiler Supplier

Delicate Processing Oil Boiler Supplier

First, the reasons gas delicate processing boiler supplier burner ignition misfire bar: 1, the ignition bar gap interposed carbon residue with oil. 2, ignition rods fragmentation. moist. Leakage. 3, the distance between the gas boiler ignition does not stick, too long or short. 4, ignition rods Insulation damage, short to ground. 5, ignition cable and transformer failure: cable, connector damage caused by a short circuit during ignition; transformer break or other fault occurs.

R & D center built and put into use, is a landmark event in the party group was founded two decades of fast, fast Group is party to enhance the quality of another milestone, is quick to understand the user side of the new window, it is to demonstrate a new gas delicate processing boiler supplier technology platform. Fang fast development center connotation of high-tech feel, quite the image of modern atmosphere, welcome your visit and visit!

The main components of the gas delicate processing boiler supplier burner gas boiler constructed by the following five systems: 1, the function that the air supply system, air supply system into the wind speed a certain amount of air to the combustion chamber, its main components are: a housing, the fan motor, fan impeller, air guns fire tube, damper controller, damper baffle, a cam adjusting mechanism diffuser plate. 2, the ignition system functions in that the ignition system ignites a mixture of air and fuel, its main components are: the ignition transformer, the ignition electrode, a high voltage electrical cable fire. A more secure electronic ignition system called ignition pulse, is widely used Zhuoyi energy saving gas boiler manufacturers. Which facilitate saving, can simply press a finger, and safe, does not occur due to unexpected accidents occur flame, once the stall state occurs, the control system can close the solenoid valve, off the gas passage. 3, system monitoring function monitoring system is to ensure that the burner safe and stable operation, the main components are flame detectors, pressure monitor, temperature monitor (see below) and the like. 4, functions of the fuel system of the fuel system is to ensure that the desired fuel burner. The fuel oil burner system are: tubing and fittings, pumps, solenoid valves, nozzles, heavy oil preheater. The gas burner mainly a filter, pressure regulator, solenoid valve, and then firing solenoid valve, the fuel valve. 5, electronic control system electronic control system command center and the focal the above system, the primary control element is a control box, with different programmer for different burners, the common programmer has: LFL series, the LAL series, LOA series, LGB series, the main difference is the time of each different program steps. Hebei gas boiler controller 1, ultra-Daquan Chinese LCD display, built-in incandescent night light, both during the day and night, the screen is clearly visible. 2, the image level animation display state, condition, valve status, alarm status, operation of the boiler at a glance. 3, CPU intelligent central processor, all the programs focused on a digital chip, scalability, high degree of automation, simple, and powerful. 4, includes a time setting, temperature setting, setting valve, a continuous setting, timer setting, and other control functions pressure setting, arbitrarily set the working state. 5, includes a low level alarm (anti-dry function), ultra high temperature alarm, alarm and other ultra-high pressure alarm and chain protection (shutdown), eliminate safety hazards. 6, to facilitate detailed self-diagnosis, records, checks and maintenance.

(9)Combustion Adjustment method of Oil-fired Gas-fired Boiler

The combustion adjustment of oil-fired gas-fired boiler is successful and the load adjustment can be carried out after turning into normal operation. At this time, the combustion situation in the furnace should be observed frequently. If the atomization of oil and gas is not good, the flame jumps, the flame hits the furnace tank, and the exhaust temperature is too high or too low, the oil pressure, oil temperature, steam volume, air pressure and steam pressure should be adjusted in time to ensure the safe and economical operation of the boiler. The oil pressure and the pressure are related to the boiler load. The adjustment of the oil pressure is realized by adjusting the pressure of the burner or the amount of oil returned. The adjustment of air pressure is achieved through the opening of the valve. When adjusting a load, enter At the same time, the air volume adjustment must be carried out synchronously to ensure the reasonable match between the oil quantity and the air volume, so as to achieve the purpose of economical operation of the boiler.

Free Chat

About Us

Contact Us