Gas Fired Steam Boiler Efficiency

Gas Fired Steam Boiler Efficiency

Such as hotel Home Hotel Group is one of the three major brands, in 300 cities in the country has nearly 2,000 hotels. Home Inns has won China Golden Pillow Award for Best Chinese economy hotel chain brand award, in 2014, Home Inns brand value of $ 420 million of selected China's top 100 brands. April 4, 2016, BTG hotel groups such as the privatization of the hotel purchase transaction has been completed delivery. In mid-2016, as a Beijing hotel with our preliminary communication, the urgent need two boilers work of heating and hot water supply. I related technical engineers and recommend it to calculate the number and size of the boiler on the hotel room as hotel Willy sharp V6-99 two models.

Energy-saving measures and methods of industrial boilers which industrial boiler energy-saving measures and methods which 1, to increase the capacity and improve the thermal efficiency of boilers and inefficient small compared to the large-capacity high-efficiency industrial boilers, can greatly improve the utilization of energy rate, so as to obtain greater economic benefits. Meanwhile, the cogeneration project enables conversion of exhaust or extraction steam turbine for heating, not only can reduce the loss of turbine exhaust steam, but also help to save coal resources. Industrial boiler thermal efficiency of China's low is a fact that can not be ignored, usually operating efficiency even lower. Therefore, improving the efficiency of industrial furnace hot pot, is crucial for energy savings. In one aspect, by improving the quality of the insulating material, thicker insulation, heat loss can be reduced. On the other hand, the use of secondary air system, can facilitate a more complete combustion of fuel, the effect is very significant. 2, the heating surface to reduce coking and fouling of industrial boiler during running, prone to coking, fouling phenomenon, resulting in increased and then decreased local resistance to the flow cross section. Not only conducive to smoke, but also so that heat transfer is reduced, further increasing the temperature of the flue gas. Industrial boilers and cleaning agent has a good cleaning effect, can be put in the appropriate amount sublimation decompose at high temperatures, with the heating surface of the coke, slag and contacts a chemical reaction can be automatically off after decomposition. Meanwhile, a method of periodically purging is also more effective in the early formation of fouling was loose state can be cleared periodically sootblowing. If the attachment is too long time, will translate into close like fouling, thus increasing the difficulty of cleaning up. 3, to ensure the quality of coal and industrial coal-fired boilers with coal is crucial, its moisture, volatile content factor for the speed of fire, as well as affecting the combustion temperature is extremely obvious. Maintain proper moisture content can be reduced with reduced leakage occurrence of coal and fly ash, coal seam and helps enhance the evacuation ventilation. If the moisture content is too high, will affect the speed and the temperature in the furnace, heat loss will be increased exhaust smoke. Industrial water boiler heating surface for scaling impact of large scale for each additional 1mm, the overall thermal efficiency of the boiler will be reduced by 3%. 4, many factors affect the lower exhaust gas temperature industrial boiler flue gas temperature, within the course of the economizer scale, cleaning up soot neglect of smoke in the furnace wall channeling smoke, poor treatment effect, can cause elevated exhaust temperature. On the one hand, to deal with the heating surface appears slagging, fouling and scale phenomena take timely measures to eliminate, minimize or avoid their presence. On the other hand, on the rear of the boiler heating surface is improved or increased. Industrial boiler flue gas temperature, objectively reflects the utilization of exhaust heat. But not as low as possible, the exhaust gas temperature is too low but not conducive to the normal operation of the boiler.

Steam and hot water boiler water level gauge fault safe hydraulic machine operating company of Henan fast boiler with small series to introduce a common fired steam boiler efficiency water gauge Problem safe operation of steam and hot water boiler water gauge failure of hydraulic machine, the causes and solutions approach a hot water boiler steam water gauge reason and common problems: 1, the water level is too low mounting table; 2, water table, even the water pipe is too small; table 3 have low level or a water level indicator, when active, only one only water table; 4, the ground water table, drain cocks no drainage; 5, a drum water level on the table is valid, another water table damage; 6, the tap water gauge screw fixed; 7, the tap water gauge leak, leaking; 8, the performance of the water table level false; 9, the drum water level in the water table irregularities two inconsistent; water gauge glass often broken; 11, water level gauge glass without guard; 12, water gauge low water level glass plate not shown in the red line instructions; 13, glass plate dirty water table, the water level observation is unclear. The main reason is because of 1-4 above design, installation or alteration of dislocation caused. When the steam boiler with a low water table position when the drum is only a case of the water table, water table because the internal balancer lowland leakage short-circuit (at that time can not be detected), resulting in the emergence of lowland water table high water level ( the so-called full of water), and the water table on the drum performance but low water level (or even probably not see the water level), then the fireman because they can not determine the true level of the boiler will go immediately and check the water level in the drum on the table, it will be very serious water shortage in container delays when the boiler accident occurred. Glass-sided water table in front of a glass sheet metal frame box lined with asbestos pad contact surface made of cardboard and then screw the cover frame and the cover pressure closely. Some even show the water level too low trust status of the water table, and take a little sewage, mistakenly steam boiler water when filled with water incident handling, accelerate the production of the accident, there is precedent for such incidents to be investigated. Then, the above-mentioned reasons hinder 5-9 problem occurs mainly boilers lasting not run when washed in water table, not routine maintenance, resulting in water gauge cocks rust, gas, water and even the block, or insufficient packing or aging deterioration. False water level phenomenon, in addition to gas, water or even the cock pipe is blocked, but also could be vapor, the water pipe connected to the water table caused by misalignment connection; steam, water tap handle installed the wrong position resulting cock closed, since there poor water quality, the boiler priming and thrown false water level. Water gauge glass is broken mainly steam, water faucet centerline not aligned, the presence of glass bending stress; long glass without expansion gap; water table is at the window glass is a cold draft, and the glass pipe quality was poor. Safe operation of hydraulic machine 1, hydraulic machine operator must be trained to master the equipment performance and operating techniques to work independently. 2, before the operation, you should clean up various debris on the mold, wipe any dirt hydraulic rod. 3, the mold must be installed hydraulic machine in case of power failure, and prohibit the collision start button, the lever foot on the footswitch. 4, installed on the upper and lower dies, the die gap adjust, unilateral allowed off-center, a good confirmation of the fixed mold pressure again. 5, before the hydraulic machine is first started working apparatus idling 5 minutes while checking whether enough oil tank, pump noise is normal, the hydraulic unit and pipes, fittings, if the piston leakage phenomenon.

At present several common boiler energy-saving technologies: usually for boiler manufacturers, it means that you are saving boiler to maximize the interests of customers, providing customers with unlimited fuel savings, the electricity consumption, water consumption and so on. But the wide range of energy-saving, does not refer to an aspect of optimization can save energy boilers, here's a look now common boiler energy-saving technologies: 1 furnace arch. Industrial boiler furnace arch is very important. Arch role is to cause the furnace hearth and the organization of the mixed gas and the radiation hot flue gas flow, ignition and combustion of the fuel in a timely manner. At present, the actual amount of industrial fired steam boiler efficiency with its rated load often do not match, the use of coal varies widely, but often with the design coal are quite different, so in actual use, often as necessary for the furnace arch modified to meet the needs of coals. Heteroaryl coal used by the inferior design coal, the boiler furnace exit gas temperature occurs is low (about 700 degrees), lower than 200 degrees design.

Free Chat

About Us

Contact Us