Gas Fired Steam Boiler In China

Gas Fired Steam Boiler In China

Fuel gas boiler automatic instrument sets the control means are included which according to the "industrial boilers Complete supply" and provides fuel gas boiler automated instrument packages supply shall include at least the following: (1) evaporation of 4t / h and 4t / h or less boiler 1 ) detection. Water gauge, vapor pressure gauges (including saturated and superheated), water pressure gauge, water thermometer, thermometer smoke, steam flow rate calculation (including less than evaporation lt / h boiler). Oil temperature, oil pressure, oil level indication, calculates fuel (gas boiler as temperature, pressure, gas), furnace exit gas temperature indication. Evaporation of 4t / h boiler flue gas oxygen content should have, furnace pressure, temperature economizer export indication. 2) regulation. Position of formula (only for non-economizer of the boiler) or continuous feedwater automatic control, automatic adjustment of a combustion boiler the combustion of heavy oil should automatically adjust the oil temperature, air pressure gas boiler there should be automatically adjusted. 3) alarm and protection. High and low water level indication and alarm, low water level limit protection, over-pressure steam indication, alarm and protection, flame protection furnace, fuel gas overpressure protection or low temperature alarm and protection. 4) Other. Auxiliary electrical control box, gas boilers should be equipped with explosion-proof electrical control equipment. (2) evaporation of 6t / h and above 6t / h boiler 1) detected. Water gauge, vapor pressure gauges (including superheated saturated), water pressure gauge, water thermometer, thermometer, smoke, water, steam pressure, water pressure indicator, calculated water flow, steam flow indication, recording and computing, oil temperature, oil pressure, oil level indication, indication and calculating the amount of oil (gas boiler as temperature, pressure, gas), economizer inlet and outlet water temperature indication, furnace exit gas temperature, exhaust gas temperature, air pressure, furnace pressure indication, Sheng Mei an inlet, an outlet indicated negative, indicating flue gas oxygen content, there is an outlet air temperature should be indicative of the boiler air preheater, the boiler superheater, there should be recorded and the superheated steam temperature indication. 2) regulation. Continuous automatic adjustment of water supply, drum, induced draft fan damper flap opening remote control, remote pump control valve (an intake gas boiler control valve), a heavy oil combustion boiler should automatically adjust the oil, gas boiler should automatically adjust the air pressure, there is superheater boiler there should automatically adjust the temperature of superheated steam. 3) alarm and protection. High and low water level indication and alarm, low water level limit protection, over voltage protection and alarm indication of heart steam, oil accident alarm system, furnace flame protection, fuel gas overpressure protection or low temperature alarm and protection. Boiler superheater should have more limited temperature of superheated steam and an alarm indication. 4) control and the other. Drums, Fan, and start and stop the pump interlock control program, drum, fan baffle opening damper indicated, shall be provided with explosion-gas boiler electrical control equipment.

Vertical fired steam boiler in china What are the advantages? With the continuous development and progress of science and technology, the boiler applications also become increasingly wide range of vertical steam boiler is not only elegant appearance, small footprint, and low power consumption, strong performance advantage. So what are the advantages of low power consumption vertical steam boiler what else? Let us to understand a small taping, convenient vertical steam boiler ignition bathing water can be discharged outwardly after two minutes a suitable temperature, without pressure, safety, a normally open tube furnace to the atmosphere, does not have any valves, to ensure safe and reliable operation. And interior of the boiler can be extracted within a few minutes, making repairs or updating the boiler is also extremely fast, short, very convenient. Second, clean the inside of the boiler fouling is a killer, many products are not remove fouling or in addition to science is not complete, but the vertical steam boiler manually to complete the removal of internal boiler fouling, will not leave any dead ends. And heating water and bathing water is not mixed with, but also add a water softener water heating cycle intervention, will not make the whole boiler fouling, very clean. Third, energy saving vertical steam boiler when the water temperature of the furnace is low, reduces the heat loss. And the use of advanced environmental protection technology, can completely smoke-free dust-free, high environmental requirements for cities to achieve energy saving effect. During use, does not produce smoke, the onset of gas boilers together as a whole, the fuel on the grate in cast from the incineration stoker opening, using a high temperature steam and coal seam combined and allowed plenty of chemical attack the combustible gas after reaction, multiple backhaul several cycles, using the pipeline full heating surface, the progress of burning thermal efficiency, heat loss can be reduced to a large extent, energy saving. Vertical steam boiler since the sale of the trust of many old and new customers praise the majority of users. Simple vertical steam boiler maintenance is also very simple, and most businesses will be responsible for after-sales maintenance boiler work, professional service staff, so please do not worry, you can rest assured purchase!

About the kind of fired steam boiler in china fuel oil boiler steam through the next, there are many main purpose, main features, a brief Automatic fuel gas steam boiler. A: The main purposes: food processing, printing and dyeing, pharmaceutical production and provide steam to provide steam sterilization, medical institutions, enterprises and institutions to provide steam for the other, the hotel's heating Automatic fuel gas steam boiler, the heating can also provide domestic hot water tank by . Second: The main features: 1, with central back burning structure, a large volume of water and gas boiler space, adaptable load capacity. 2, the indoor micro-pressure flame automatic steam boiler fuel combustion, the flame is fully extended, enhanced heat transfer, thereby reducing convective heating area, reducing the cost of the boiler. Smoke flow resistance is small, low-power consumption operation, operating cost savings. 3, in addition to the conventional four level height control, an additional level detector 5, the detection bit will stop when the boiler water, alarm, to ensure safe operation of the boiler. 4, the front smoke box special heat insulation materials, high temperature, low thermal conductivity, good anti-radical quenching heat capacity, greatly extending the life center back burning boiler before the smoke box, the furnace insulation is multilayer glass wool , light weight, low heat loss. 5, automatic oil-fired boiler steam pressure is controlled by Danfoss and Danfoss pressure controller and pressure transmitters joint control, pressure controller is responsible for ultra-high pressure interlock protection, prohibits burner working and alarm; pressure transmitter responsible for combustion engine to work to achieve some or all of control, to achieve automatic control of the exact steam pressure and steam pressure in the pressure range provided by a touch screen, detecting a pressure up to 0.002 MPa, more accurate pressure control. Thus avoiding a pressure controller general requirements of the production and the high vapor pressure of low pressure gas boiler or the actual requirements of the production of high pressure and low pressure gas boiler can not meet the disadvantages of the production requirements. 6, flue gas condenser fast side (optional) by the national utility patent, requires efficient use of steel-aluminum sheet Chi spiral tube heat exchanger, heat transfer surface is sufficient, the small side of the flue gas resistance of the system to meet the general burner. With flue gas condenser heat boiler efficiency can be improved more than 8%, the fuel gas savings of nearly 10%. These are the simple on automatic steam boiler fuel introduction want to be useful.

First Affiliated Hospital of Bengbu fully implement the national environmental protection policies, strict screening of clean boiler as the supply of medical supplies disinfection and ward heating equipment. Fast boiler with its focus on research and development of clean-type gas boiler two decades of experience in the industry favored. The partnership, to provide fast boiler First Affiliated Hospital of Bengbu Medical College, a WNS20-1.25-YQ one condensing fired steam boiler in china, in terms of design, manufacture, installation and other aspects of strict checks to enhance the thermal efficiency of the boiler as well as truly Energy saving and environmental protection.

Free Chat

About Us

Contact Us