Gas Or Diesel Fired Steam Boiler

Gas Or Diesel Fired Steam Boiler

Gas boiler szs 1 emergency shutdown procedures, if necessary emergency shutdown generally, when the boiler encounters one of the following, operation should be stopped in case of emergency; (1) allow the boiler steam pressure exceeds a safe pressure, fueling is stopped strengthen water supply, measures the wind pressure continues to rise. (2) boiler severe water shortages. Water meter can not see the water level. After being called water, the water level of sight. (3) When the severe water boilers, boiler water level is higher than the highest water level is visible, but the emission level not yet seen. (4) increase in boiler water, take other measures, the water level will continue to decline. (5) water supply device is turned off, standby equipment. (6) all water level gauge or invalid. (7) All the safety valve all the failures. (8) All all-off failure drain valve. (9) causing damage to the boiler pressure element (e.g., boiler tubes, etc.), or endanger the safety of the device. (10) boiler is a serious threat to other events and safety equipment. 2, natural gas boiler operation method szs immediate emergency stop operation of the controller, the boiler is off, closing the front of the boiler gas valve to stop the gas supply. The or diesel fired steam boiler competent completely separated, opening the exhaust air valve or safety valve steam pressure. Due to lack of water, the boiler is not allowed into the boiler, the steam is not discharged to reduce pressure. No shortage of water, cold water can drain down alternate method, the water level remains complete accident should immediately stop the water supply, water reducing combustion (fire artificially changed into a small fire), play an open valve while opening the main steam pipe and the drain valve cylinder to prevent the steam to carry large amounts of water, water. In the shutdown process, the cooling rate of the furnace should not be too fast to avoid flue compression member and the expander is damaged suddenly cooled. 3, emergency shutdown processing method szs natural gas boiler in the case of emergency shutdown, due to the nature of the accident, the following may take a different approach: (1) rapid flame treatment emergency shutdown, the burner first station, and closing the valve flame gas supply is stopped after the cut valve, to maintain the water level is normal. (2) rapidly cooling the furnace or water if there is no water leakage during an emergency stop, the cooling time can be shortened to the boiler water and sanitation and reduce the pressure. When the boiler water temperature down to 80 degrees Celsius, boiler water can be discharged. If the boiler severe water shortages, the boiler can not cool quickly in the event of an outage. Non-water to the furnace, or explode. accident. (B) natural gas boiler shutdown SZS normal shutdown (complete shutdown, shutdown maintenance) procedures which can be used when needed repair or stop steam boiler. 1. If one of these faults, the leaders agreed, the boiler can be temporarily closed repair: bilge faucets, riveted joints leak, damaged tubes, the waterwall tubes, the heating tube, the flue gas contacts the drum, the head, off pipe insulation, water supply system, combustion system, a serious fail-safe accessories, in need of repair. 2, a temporary repair (or normal shutdown) the method of operation in order to stop the burner, for closing the valve. Boiler feed water to 2cm above the normal water level, to stop water supply, reduce the pressure. 3. Turn the main steam valve, open the traps, and steam boiler operation, reliable water separator. 4, boiler feed water close electric valve and manual valve, boiler feedwater reliable cutting. When the steam pressure drops to zero, the water can be supplied and discharged alternately, so that water is gradually cooled furnace, when the temperature drops to 50 degrees Celsius (or hand potshell touch feeling hot pan head), can be completely discharging furnace boiler water water . Before water, open the air valve on the boiler or lift safety valve. At this point, you can enter the furnace for inspection and repair. Cooling the furnace must be kept slow, non-violent cooling and damage to the boiler, the boiler can be stopped from the repair into the furnace, the cooling time is generally less than 24 hours. Close the furnace over 24 hours, shut off the gas supply valve at the regulator, and open the gas conduit pipe is responsible, in the exhaust gas pipeline.

Since 2019, Taiyuan continue to adhere to the principle of priority to improve air quality, in order to significantly reduce heavy pollution weather as the main direction, ongoing action to combat air pollution, management depth to promote coal-fired boiler to achieve 35 tons of steam coal-fired boilers "clear zero".

In accordance with the gas will change, given the need for, after the first stand broken, do not break the principle of non-stand, Taiyuan will continue to carry out the transformation of rural areas, clean heating, heating is expected to complete the transformation of 30,000 before the end of October, the city's rural areas clean heating coverage rate reached 70%.

To reduce coal pollution, coal-fired boiler will also promote the in-depth treatment. October 1, seven more than 65 tons of steam coal-fired boilers and ultra-low emissions completed the transformation. Seven out of 35 tons of steam coal-fired boilers to achieve 35 tons of steam coal-fired boilers all clear.

In the region of the pollution control aspect, the binding improved air quality requirements, the complete electricity instead of coal, coal gas for generation of clean alternative energy area, included in "ban on coal zone", the implementation of joint sheet control. Meanwhile, to further increase the intensity of investigation ban within the "ban on coal zone" small coal-fired facilities, enhance the level of protection clean heating, ensure clean heating effect, and resolutely put an end to bulk coal burning complex, consolidate the "ban on coal zone" construction achievements.

In terms of market control, prohibit the use of more than 1% sulfur, ash than 16% of the civilian bulk coal. Before the end of the civil bulk coal sampling of coal sales business monthly coverage rate of 10%, annual sampling coverage of 100%. Investigated sales of low quality coal units and individuals in accordance with law, concentrate on cleaning up, straighten, banning non-compliance bulk coal supply channels, to crack down on the use of low-quality coal sales behavior, non-coal washery slime, the coal into the civilian market.

The use of gas or diesel fired steam boiler added to give businesses what benefits? National emphasis on energy conservation increased year by year, which also contributed to the gas steam boiler flourish among industry, under the premise of environmental policies and to efficiency gains, companies are willing to choose both energy-saving, and high thermal efficiency of gas-fired boiler. Gas steam boiler in addition to providing sufficient high-temperature steam, but also can reduce fuel cost by reducing the combustion load input. The use of gas steam boiler will bring any significant benefits, let's take a look. 1, the biggest benefit is the economic use of gas steam boiler can save a lot of fuel costs for businesses, you do not need to spend lots of money to purchase a large amount of coal fuel, just use good cleanliness of natural gas will be able to output enough steam; they also do not We need the fuel storage site, only need to connect to the pipeline. 2, security is well known that natural gas is a very safe and stable, non-toxic and pollution-free, good cleanliness of fuel, liquefied petroleum gas or gas leak after not deposited on the ground, and even cause accidents will burn again. Process gas steam boiler during conveying gas selected gas is the most secure, but also easily found after leakage during use and therefore is the most secure way. 3, convenient gas steam boiler in the use, operation is very convenient, so will much favored by all walks of life. Because the use of all natural gas pipeline, a sustained run without any problems. Eliminating the need to transport coal use and clean-up or stacking cinder and other tedious work. 4. Clean the reason why gas steam boiler in the market to get a high rating, but also because it is clean and not contaminated during use, and does not produce black bottom of the pot, there is no air pollution. Thus, in use, compared to other boiler is the cleanest way.

What are the common type gas or diesel fired steam boiler have? Common types of gas steam boiler is as follows: fuel (gas) is oil or gas as fuel, burning the fuel using a burner to heat the gas as steam carrier. Structure is generally divided into two kinds of vertical, horizontal, mainly based on these two forms of device space height. Gas based on coal as fuel, gas and steam as a heat carrier. Hand generally divided into vertical burn, horizontal cylindrical type, three kinds of gas fired horizontal plane structure, mainly based on labor intensity stoker thereby form these three points. For electric heating electric heating oil furnace, heat is generated and transmitted by the electrical heating element is immersed in the gas and steam to steam gas medium by the circulation pump to force liquid recycle gas steam, with a heat transfer to or more heating equipment, heating equipment after unloading, re-circulation pump, back to the heater, and then absorb heat, heat transferred to the device, again and again, to achieve a continuous heat transfer the temperature of the heated object rises, the heating to achieve process requirements.

Free Chat

About Us

Contact Us