Heavy Oil Autocontrolled Steam Boiler

Heavy Oil Autocontrolled Steam Boiler

Electric autocontrolled steam boiler before use Preparation 1, the operator must understand how the present electric steam boiler, location, performance and working methods of the various accessories. 2, check oil combustion, and each nozzle connection, power supply and the burner, the pump, the boiler installation accessory. 3, clearly the main steam valve open, after closing the normal close it. 4, check the electric steam boiler water level, water level confirmation flexible, normal position. 5, the pressure regulator is properly tuned, regulate combustion damper.

Industrial gas autocontrolled steam boiler for industrial use industrial gas steam boiler is a low-pressure gas steam boiler, but its high thermal conductivity temperature of the liquid inside, and the liquid explosive is mostly, if working in industrial gas steam boiler thrown thermally conductive fluid leak and cause a fire or even a large possibility of an explosion, which is very dangerous, so run industrial gas steam boiler safety is often worth the length of the face. Because the range of high temperatures (above 320 ℃), low voltage (0.3 to 0.5MPa), the heating temperature can be precisely controlled, it can replace the original steam boiler heating. Industrial gas steam boiler is heated up to a temperature of 350 ℃, molten salt furnace is heated up to a temperature of 530 ℃. Because the ash can not be produced by industrial combustion gas steam boiler fuel gas, if the gas and air mixture into the furnace is injected within a certain range may explode. Gas steam boiler operating temperatures above 400 ℃ oil and molten salt heat transfer medium, having a molten salt heat steam than the gas lifetime advantages, but otherwise are at a significant disadvantage, in particular the complexity of running the system.

Recently, Jinan City, Shandong Province People's Government issued and implemented the "2018 Beijing and Tianjin and the surrounding regions - 2019 autumn and winter tackling air pollution comprehensive management action plan" to inform the implementation of the program, requires the consolidation of ambient air quality improvement achievements, promote air quality continues to improve. On October 1, 2018 to March 31, March 2019, and all the city county fine particulate matter (of PM2.5) mean concentrations fell more than 2%, severe pollution and over several days up declining.

"Implementation plan" will be based on four construction industry, energy, transport and land use optimization adjustments to promote clean heating, public transferrin, enterprises mentioned standard upgrade, dust remediation, focusing on the consolidation of "scattered pollution" enterprise comprehensive rectification results, ruthless grasping diesel trucks, industrial furnaces and rectification of volatile organic compounds, heavy pollution to the implementation of the weather in autumn and winter peak load shifting production to strengthen joint prevention and control among regions, strengthen law enforcement supervision.

1, continued implementation of the total coal consumption control, strict implementation of national, provincial coal consumption reduction of about alternative work arrangements, and the development of alternatives seriously implement the Jinan City, the work reduction of coal consumption, coal consumption control tasks break down into individual counties, total coal consumption to achieve a steady decline. 2018, the city's total coal consumption control in less than 17.14 million tons.

2, effectively promote clean heating to the town (street) or the county as a unit as a whole. As of 2020, the city's pre-season heating living and improve the basic motivation for heating coal for alternative tasks, to develop a three-year implementation program to determine the annual task of governance. Taking into account the agricultural greenhouses, animal building bulk coal governance and to proceed with energy-saving buildings to improve energy efficiency. The county should proceed from reality, according to local conditions, reasonably determine the transformation of technical route, should the electric power, gas should the gas, the coal should be coal, should be hot is hot, and actively promote the use of solar thermal and centralized biomass utilization; adhere to highlight focus, give priority to urban life and motivation for heating gas demand, priority to promoting the urban bulk coal cleared. Gas will adhere to the reform, to change the electric set, on the basis of priority to the protection of residents in 2017 has started "coal to gas," "coal to electricity" project on gas electricity, gas and new year according to the actual supply and heating period the ability to reasonably determine the residents' coal to gas, "" coal to electricity "households; insist on legislation after the break, substitution of gas for coal to electricity instead of coal and other alternatives, in the implementation of air power is not the case, the original heating facilities will not be removed. In accordance with national, provincial requirements, to complete the clean winter heating construction tasks 33000.

3, complete replacement of the bulk coal areas to be designated as high-pollution fuel combustion zone ban in accordance with the provisions, shall not be burning coal for use again. Severely crack down on sales of low quality coal combustion, to ensure the quality of coal used in line with national and local coal quality standards.

Gas-fired autocontrolled steam boiler abnormal situation, how should we deal with it? When we use gas steam boiler, failure or abnormal phenomena it is inevitable, but in order not to affect the normal use, in the event of a problem gas steam boiler to be timely processing solutions, then the face of all kinds of circumstances, we should how to handle it? Share some of the ways we deal with unusual circumstances. If only gas steam boiler circulating pump abnormalities, such as its current decreases, the pump outlet pressure back to zero, which indicates no oil pump is idle, it may be caused by oil vaporization. Yang identify the reasons therefore first vaporized measures; such as clogging of the filter circulating pump bypass opening evacuated immediately clean the filter; heat transfer fluid as a result of added aqueous or decomposed gases are not excluded in the system, should immediately open the vent an exhaust valve. Circulation pump pressure constant, the current increases and the flow drops, deterioration of the thermally conductive fluid, the viscosity increased, should be replaced or regenerated. New heat transfer fluid as a result of decomposition of aqueous or excluded gases in the system, should immediately open the vent valve of the exhaust gas. When the current is lower than normal circulation pump, the circulation pump efficiency is decreased, the flow rate decline may be heating pipes plug fouling, stainless steel chain should be cleaned. If the gas steam boiler before and after the filter increased in pressure, the pump inlet pressure drops, the filter may be stuck, the opening of the bypass, disassemble and clean the filter. In addition to its low furnace outlet temperature liquid phase heat carrier, mainly for lack of heat fouling problems, it is timely soot blowing. Gas steam boiler grate more common problem is stuck, there are reasons including breaking grate or the grate off loose pins; coal grate has stuck to metallic inclusions; arched grate; slag is sinking the tip of the grate stuck. In response to this phenomenon, the required reverse hand grate plate debris removal, replacement breaking grate after the start, then jammed as startup, stop the rotation of the reasons detailed inspection to resolve. But also to re-adjust the adjustment screw on both sides of the grate tension, if still does not work, we need to replace the sprocket.