Horizontal Type Oil Fired Steam Boiler

Horizontal Type Oil Fired Steam Boiler

10 tons of gas turbine horizontal type fired steam boiler burner it currently requires 10 tons of steam gas boiler steam boiler there are two types WNS10-1.25-Q SZS10-1.25-Q, and two kinds, i.e., three horizontal wet return back structure and vertical type double drum "D" type arrangement quick water tube boiler. It consists of upper and lower drum, membrane wall, superheater, economizer and convection bank composition, the burner disposed on the front wall, the fuel combustion in the furnace, the flue gas through the first convection bank, superheater, a second convection economizer tubes and into the chimney. 10 tons of gas boiler burners have split and one-piece points, integrated burner fan I see are axial fans, centrifugal fans with split, 90% of the 10 tons of gas boiler burner all-in-one, as to form two burner what a good way, this has yet to be explored. SZS10-1.25-Q has the following features in gas boiler: The product has the following characteristics: ⑴ This double boiler drum "D" type arrangement, a compact, small footprint, good flame fullness. ⑵ boiler lower support mode can be free to expand upwards. ⑶ using membrane wall furnace wall structure which reduces maintenance work and use of refractory bricks. This boiler ⑷ fender an airtight closed welded structure, good sealing furnace wall; outer layer of pressed boards, appearance, beautiful. ⑸ this boiler furnace inspection hole is provided for the use, maintenance provides a great convenience. Roof has explosion-proof doors. This quick ⑹ boiler structure can effectively shorten the installation cycle. ⑺ high thermal resistance material as a heat insulating layer, good insulation properties. ⑻ economizer arranged tail, can effectively control the exhaust gas temperature, high thermal efficiency of the boiler. ⑼ whole boiler steel holder on a strong base, convenient installation and transportation. ⑽ boiler heating surface has a surplus, soft drinks and large enough space to ensure the stability of the boiler parameters. ⑾ using automatic burner, combustion efficiency and an ignition control program and overpressure, flame protection. ⑿ continuous electrically adjustable water supply, and having a low water level alarm, the protection function chain. ⒀ using spray desuperheater, sensitive temperature adjustment, temperature control large amplitude. Second, the structure Introduction boiler 1, the main evaporation rated specifications: D = 10t / h of superheated steam temperature: t = 300 ℃ superheated steam pressure: P = 1.25MPa water temperature: tgs = 20 ℃ (except normal saline) boiler efficiency: η = 92.6% exhaust temperature: tpy = 136.3 ℃ desuperheater tYPE: hydrostatic pressure test boiler desuperheater spray: 1.75 MPa number of valve: drum 2 PN2.5, DN80 full open spring valve overheating an outlet header PN2.5, DN50 full open spring valve design of the fuel: 0 light diesel oil (Qydw = 41870kJ / kg); consumption 749.9kg / h of natural gas (Qydw = 37060kJ / Nm3); 847.3 consumption Nm3 / h

Class B, a predetermined alarm and an oil pump Heat Transfer Material Heater described organic heat boiler, which is a boiler, but also the more common and popular. So, based on this, then, will explain the boiler-related knowledge, so that we can know and understand it, and at the same time, can increase their expertise in this area. So, based on this, then, will be immediately proceed to enhance everyone's learning efficiency. 1. Organic Heat Carrier boiler organic heat carrier, which specifically refers to what? It belongs to the hazardous chemicals it? In addition, B-class boiler, is how these two provisions of the vapor and liquid organic heat carrier boiler? Organic heat carrier boiler organic heat carrier, the specific terms of the case, which means that thermal oil is an oil. Due to its ignition point and flash point is relatively high, therefore, does not belong to dangerous chemicals. And Class B boiler, gas and liquid phases of the two predetermined specific species, is: Q is greater than 0.7MW gas furnace, the furnace is liquid Q is greater than 4.2MW. 2. Organic Heat Carrier boilers, pumps and expansion tank low level alarm, whether there is a connection? Organic Heat Carrier boilers, pumps and expansion tank low level alarm, there is no necessary connection, because, pump alarm, there is only pressure alarm, and the expansion tank low level, it is a lack of oil expansion tank, which when should oiling system to perform work up the oil. 3.G1 certificate, which it can operate the boiler will be? Among them, this one contains organic heat carrier boiler? G1 syndrome, type boiler which can operate, for: rated pressure not greater than 0.4MPa, and the evaporation amount is not greater than the rated horizontal type fired steam boiler 0.5t / h of. In addition, there is not greater than the rated power of 0.7MW hot water boilers and organic heat carrier boiler two boiler. These questions are all about this kind of boiler organic heat carrier boiler, and also we must know and master, because the only way to make yourself and learn something instead of nothing. And, for us it is also a very good opportunity to learn, therefore, should cherish is.

ASME is referred to as "the American Society of Mechanical Engineers", mainly dedicated to the development of machinery industry standards, and was recognized by most countries in the world. Get ASME certification is fast boiler and pressure vessel products to the international market, the only way to obtain a certificate issued by ASME and stamp means getting the products exported to international market, "pass."

Oil-fired boiler work and preparation before purchase if necessary fuel boiler induced draft fan, this is a particular kind of boiler, and all of us concerned, but also need to have a comprehensive knowledge and understanding, so as to know how to correct and rational use of oil-fired boilers this a boiler at the same time to achieve the purpose, can also increase their expertise in this area. Whether to do some preparatory work before 1 oil-fired boilers to buy? Oil-fired boiler product before making the purchase, it is the need to do some preparation work. Moreover, this work has two purposes, first, the importance of this work reflects the product purchase, and second, to avoid the wrong choice appears. In the specific content of the work, first have a clear understanding of the environment and the requirements of the product, the second is some basic information to understand the product and production manufacturers, including product origin, specifications, size, performance and technical parameters, product quality and price and product service, in the process of considering these factors are indispensable to ensure accurate judgments and the correct choice. 2. Fuel different classification criteria boiler Are there different kinds? Oil-fired boiler, which is a specific kind of boiler, so, as with a normal boiler, at different classification criteria corresponding to different species, therefore, the answer to this question is yes. If the kind of fuel according to points, can be divided into two oil-fired boilers and boiler heavy gas oil boilers, diesel or gas oil refers to the kerosene, heavy oil is extracted by means gasoline or diesel oil as the rest of the heavy oil. In addition, the boiler according to purpose to points, can be divided into a fuel oil-fired boiler water boilers, hot water boiler fuel, heating fuel boilers, boiler and fuel oil bath and horizontal type fired steam boiler these. 3. The oil-fired boiler fuel consumption calculations it important? From a professional point of view, to calculate oil-fired boiler fuel consumption is very important work, and careless treatment can not be ignored, because if get the wrong result, it will affect the normal use of the boiler. In addition, we also need to know is that there is a corresponding formula, under normal circumstances the use of boilers, boiler output if different, then the boiler fuel consumption is not the same. 4. Does fuel boilers must have induced draft fan? There are requirements for the quality of its oil do? Whether fuel boilers must have induced draft fan, according to this aspect of professional presentation, the answer is not necessarily, because depends on whether the specific circumstances so require, if the amount of air supply and flue fuel ratio appropriate and clear then use the blower can be. This kind of boiler oil-fired boiler, its oil quality is not clearly defined requirements, but in the use, certainly requires better quality fuel, so as to ensure the boiler work properly.

Free Chat

About Us

Contact Us