Industrial 18 Ton Boilers Dealer

Industrial 18 Ton Boilers Dealer

First Affiliated Hospital of Bengbu Medical College, responsible for staff to feedback to our company, this industrial 18 ton boilers dealer to use less smoke production, in line with the special requirements of the hospital surroundings and national requirements for flue gas emissions. During the boiler installation and operation, square quick technical staff also always concerned about the dynamic boiler, parties can feel really real fast customer service, using fast boiler is assured. --customer feedback

General Electric industrial 18 ton boilers dealer according to the size decontamination decontamination apparatus has the following two ways: 1, in the station equipment. Decontamination station generally higher, before the device is a heater or a return pipe, in order to avoid debris flowing into the heater; 2, device in the water supply pipe outside the station. Decontamination station at the well outside the home are generally small, typically in water supply equipment, equipment and some system, some system is not the device, it is to avoid the effect of debris into the user's radiator.

When the industrial 18 ton boilers dealer shutdown immediately following occurs please: When the device after prolonged use, it may be because of time or frequency of use, resulting in some failures in boiler use, some faults may not be very critical, but some when a failure occurs, in order to prevent unnecessary accidents, we need an immediate shutdown. Then, the following will introduce you to look at the situation requires an immediate shutdown of the boiler: 1, all of the water table or valve failure. 2, to pump all the water system failure or malfunction, not water to the pot. 3, the boiler water level is lower than a lower edge of the visible water table. 4, boiler water level exceeds the visible level (full of water), turn on the water can not be seen by the water level. 5, the boiler element damaged, thereby endangering the safety of operating personnel. 6, increasing water supply and other measures, but the water level continues to drop. 7 other abnormal situations endanger the safe operation of the boiler. Emergency shutdown procedures. 8, combustion equipment damage, furnace or boiler structure collapsed wall is red-hot, a serious threat to the safe operation of the boiler. When the boiler the following cases, be sure to shutdown immediately, in addition, we want to prevent the emergence of these boiler failure. So, in their daily work its proper inspection, maintenance, cleaning, is very important. Three Notes cc boiler installation: small series

Condensing industrial 18 ton boilers dealer condensing heat exchanger selection problem: all parts of the condensing boiler is in contact with the condensate, such as a condensing heat exchanger, flue gas duct and the induced draft fan must be suitable corrosion resistant material. I copper, aluminum two materials were compared, the aluminum alloy material found suitable for this research project more. ① copper and aluminum fin efficiency comparison: Ek reinforcement measure the relative percentages of the respective physical quantity of copper instead of aluminum fins fin (fin efficiency, heat transfer, heat transfer coefficient, etc.) change with the fin efficiency heat conducting fins improve the coefficient increases. However, the specific amplitude increases, the fin is limited by Movies Ⅱ material itself, the structure and the air-side heat transfer coefficient. In this study, we fin thickness of 0.02-0.18mm, and the fin height of 5-30mm air side heat transfer coefficient of 60 ~ 160WW / (m2 • K) of copper and aluminum fins of fin fins fin efficiency were analyzed and compared. After comparison, the copper fin fin efficiency is higher than about 0.938% aluminum fin ~ 29.86%. Different structures and conditions of copper, aluminum fins ② overall heat transfer coefficient on the refrigerant side heat transfer area per unit comparison: Typically, the total surface area of ​​the side fins An overall heat transfer coefficient of the finned tube can be calculated as a reference :

Free Chat

About Us

Contact Us