Iraq Gas Fired Hot Water Boiler

Iraq Gas Fired Hot Water Boiler

Principles of steam boilers and solutions hydraulic external gear: told you about the principles of steam boilers and solutions for steam boiler hydraulic external gear in accordance with the fuel (electricity, oil, gas) can be divided into electric steam boilers, oil steam boiler, gas steam boiler three kinds; constructed according to the steam boiler can be divided into vertical, horizontal steam boiler, steam boiler compact than a single, double return of the vertical structure, a large steam boiler plurality of three-pass horizontal structure. If the classification according to top standards, in the form of steam boilers on the lot, would like to give an ordinary packaged boiler say four tons vapor. Water in the steam drum is heated to become vapor, fire emits heat in the furnace, it is the principle of the steam boiler. Steam boiler combustion section and drive means by a chain grate, a combustion chamber together with the pan rack frame formed on a grate composition. Four weeks envelope refractories.

The price of gas boiler characteristics and maintenance of gas boilers Products: gas boiler includes a gas water boiler, gas iraq fired hot water boiler, gas steam boilers, gas hot water boiler which is also known as gas heating boilers and gas boilers bath, as the name suggests refers to gas boiler it is the fuel for the gas boilers, gas boilers and oil-fired boiler, electric boiler compared to the most economical, most people have opted for a gas boiler as steam, heating, boiler equipment for bathing. Gas boiler Features: 1, large font display temperature, easy to grasp and boiler operating conditions of the system, the water temperature can be freely set from 10 ℃ to 90 ℃, automatic boiler or heating system to provide users with life, bath with hot water. 2, the control system controls the circulation pump start and stop in accordance with the temperature of boiler water, boiler water circulating pump starts when the water reaches an upper limit temperature, lower than the hot water circulation pump stops when the water temperature lower limit. 3, three horizontal gas bath boiler return all wet back structure, using a large furnace, rough smoke tube design, increased furnace radiation heat absorption, the effective energy saving. Using threaded pipe and waveform furnace, greatly enhanced heat transfer effect, greatly saving fuel consumption. 4, while the machine is equipped with thermal protection (ultrahigh temperature furnace, the burner is automatically stopped and an alarm buzzer, the second over protection (the boiler shell temperature exceeds 105 deg.] C, the secondary circuit is automatically cut off), the lack of anti-dry protection of water (when water is lower than the low water level of the furnace, the boiler is stopped and an alarm beep), a boiler leakage protection (the control system detects electrical leakage, short circuit, automatically cut off the power) .5, according to the boiler pressure design , no pressure in the boiler state, there is no safety hazard with advanced multi-layer insulation centrifugal glass wool, steel for packaging famous white color, heat loss, beauty care and anti-rust gas boiler: 1, gas-fired boiler during operation Note the following points: (1) does not allow pressurized gas boiler furnace combustion or smoke, because the manhole cover easy to burn stoker; not on the water bottom (2) gas boiler ground surface to prevent corrosion .2 moisture, gas boiler runs every 2-3 weeks, should be checked once a .3, gas boiler run after every 3-6 months, should conduct a comprehensive inspection shutdown maintenance: (1) internal and external gas boiler inspection, such as by Weld parts, steel inside and outside for corrosion phenomenon, if found serious deficiencies should be repaired, if the repairs were not serious defects also until the next shutdown, if there is suspicious, but does not affect safety, should make a record for future reference; (2) can be checked and the water boiler primer coating to prevent corrosion .4, gas boilers and boiler paint base at least once a year .5, often of unused gas boiler maintenance methods: dry and wet two kinds, one month shutdown, care should be taken dry method, wet shutdown can be less than one month regimen (1) dry regimen: after shutdown of the furnace to the discharge water will completely remove the dirt inside , rinse, drying in the furnace with Weihuo (be careful not to fire), and then the bulk quicklime 10-30 millimeters in diameter installed sub-plate, placed in the drum, without contacting the metal with lime, quicklime by weight, calculated to the drum volume 8 kg per cubic meter, then all manholes, hand holes pipe valve closed, checked every three months, such as lime ingredients like broken, i.e. the need to replace the boiler should be re-run Quicklime and disk unloading (2) Wet regimen: After Shutdown of the water discharge furnace, the inside completely remove the dirt, rinse, refill treated water to the full, the water was heated to 100 deg.] C oven, so that the water exhaust gas out of the furnace, and then close all valves, cold climates where moisture can not support the use of law, so as not to damage the boiler furnace water freezes.

Importance of continuous Feedwater equipment in Gas-fired Steam BoilerThere are two kinds of feed water methods for steam boiler, steam feed water and electric feed water. Steam water supply equipment mainly refers to water injector and steam reciprocating pump, usually acting as backup water supply equipment in boiler. Another commonly used electric feed-water method is through the electric centrifugal pump and vortex pump to feed the water. During the operation of steam boiler, the feed water equipment is usually required to have the active control function. The water level can be lowered to a certain azimuth to actively open the pump to feed the boiler, and the inlet water to a certain direction can also actively stop the pump. Hot water boilers can also be recycled according to in / out water temperature or heating conditions. So gas boilers are usually equipped Use an electric centrifugal pump or vortex pump instead of steam-powered feed-water equipment. The feed-water equipment in gas-fired steam boiler is a very important equipment in all boiler systems. It is responsible for supplying raw materials to steam boilers; allowing it to produce the steam it needs to be used. In the process of boiler operation, it is necessary for the water supply equipment to run synchronously so as to supply water to the boiler continuously, so that the boiler can get enough water supply to run normally and safely.

Jinzhou construction and installation company needs an electric heating iraq fired hot water boiler house construction, after screening and comparison of various brand boiler industry, our excellent results in the cleaning of the boiler industry has been attracted to each other, in mid-2016, the Jinzhou construction and installation the company I signed with an electric heating pressure hot water boiler.

Free Chat

About Us

Contact Us