Textile Oil Boiler Dealer Price

Textile Oil Boiler Dealer Price

flameout state and treatment method of oil-fired textile boiler dealer price

The customer asked: what is the status of the fuel-fired boiler after it is put out? How to judge whether the burning oil and gas boiler is extinguished?

Prevent explosion of the furnace, the fuel (gas) textile boiler dealer price flame protection means must be provided, is a function of combustion (including ignition, combustion or misfires when halfway off, typically within five seconds re-ignition furnace in the monitoring, within 1 second running off into the oil (gas) solenoid valve, and turns on and audible alarm signal, when the blower continues to operate, the residual gas was purged of combustible furnace, after 20 to 30 seconds purge, automatically cut off the blower and various auxiliary power boiler stop running.) by the flame monitoring and control device component. Role is to monitor the flame control device signals the presence of a flame or interrupted.

School education is the foundation for development of our country, to provide environmental and healthy living environment for students is our top priority school. Winter is fast approaching, fast textile boiler dealer price heating and for us to solve the problem of the coexistence of environmental protection, give us tremendous help provide heating in winter. --customer feedback

Brewery textile boiler dealer price burners should choose how to select the furnace temperature and pressure. Recorder manufacturer must indicate what type of device it belongs to the device, the furnace pressure is positive or negative, pressure is how much, how high the temperature is. Because different types of furnace temperature, different structures of the burner, use of different materials, selected as a high pressure burner furnace burners to overcome the low pressure furnace burners. When the calorific value of gas pressure is selected as the fuel gas, due to the variety of different calorific value of gas, the pressure is inconsistent, so the choice of the manufacturer and described in the fuel burner type, the number of heating value, to select the appropriate number combustor pressure, in order to avoid the risk of an incorrect selection. For this mode the device for adjusting the required temperature accuracy can select some fire (only one burner in a secondary operating mode Fire (burner operation mode to fire small, the work of two point mutations, two operation switching point mutation) in operating point), progressive (small fire, small fire) mode. Operating point, switching between the two stable operating points progressively. Burner adjustment (at any point within the operating range of the combustor burner combustion mode can be left behind, to balance the requirements for the heater system output). If you choose to spray heavy oil, heavy oil burner may be the result of a mechanical fuel atomizer, F middle area atomizer burner and different geographical environment, different environments for different viscosity requirements of the burner differ .

Free Chat

About Us

Contact Us