Wns Diesel Gas Steam Boiler 1 Ton

Wns Diesel Gas Steam Boiler 1 Ton

The use of electric wns diesel steam boiler 1 tons What are the requirements? General Electric steam boiler is to be converted into an energy form of heat, through the conversion of the boiler can be turned into heat energy of steam or hot water, which requires the use of gas when you have it steam boiler, steam boiler in the first before water is necessary to check each valve, steam pipe, pressure variations, water tables, etc. also note the drain valve is not also intact. after the steam inside the boiler should be kept clean to be used, to which water is after softening the outer glass tube in the water table to be equipped with rugged protective cover, but also to keep it clean after each use it is necessary to scrub, as well as to see the water level of the water table there rise or fall, if it stops phenomenon, we must immediately investigate the cause. after the adjustment is not just above the steam boiler safety valve.

Note the choice of industrial boilers from the first industrial revolution to develop microbial technology, and upgrading various products continue to emerge, led us to the development of human civilization from the original backward to technological civilization, to the boiler, for example, since the last century, there has been a cylinder since the boiler-shaped, with the needs of science and technology and production, from simple to complex, from single to serialization, boiler technology are developing rapidly, the good reputation of industrial boilers companies choose to share precautions industrial boilers; first, the coal use; the design of the cell structure based on coal boiler components as the design basis, select the boiler should pay attention to adjust to the type of coal in the region. It recommended new, high-efficiency, high-tech, high-quality, durable industrial boilers; second, parameter selection; industrial efficiency boiler work normally when approaching the highest efficiency rating, as the load decreases efficiency has declined. Boiler capacity is generally selected: it generates a large steam than the actual gas consumption, such as the required parameters and actual parameters difficult to match industrial boilers, high boilers in this case a gear selection parameter. Selection of auxiliary boiler should also refer to the above principles, to avoid the "big horse car"; third, the number of choices; normal maintenance of industrial boilers and boiler shutdown is a number of factors, but also pay attention to: the boiler room shall not exceed the number of boiler economizers work load, install boiler economizer device purpose is to avoid too much heat when the smoke away. Improve the thermal efficiency of the boiler, is provided in the back pass boiler economizer heating surfaces, the use of flue gas heating boiler feed water, to save energy, economizer after the installation, the boiler increases the thermal energy required for heating the feedwater, boiler water and so reducing the temperature difference between the water supply, reduce the burden of heating boiler feed water. Cause excessive number of boiler economizer can not play a role, resulting in waste of energy; These are high-quality industrial boiler company to share some notes selected industrial boilers; vast land of our country, many places are rich in coal, resulting in different types of coal , which has also become a basis for selection of parameters and select the number of boilers enable us to be more effective in energy conservation, to achieve a win-win.

Process safety valve check valve gas wns diesel steam boiler 1 ton is one of the three safety accessories gas steam boiler, when the boiler pressure is too high, the pressure relief valve will automatically exhaust, gas steam boiler is the important safety equipment . The case of a new installation, overhaul, lack of consumer safety valve shutdown and restart more than three consecutive months, have had to re-check safety valve, safety valve to ensure accurate and reliable by the company safety officer, boiler technician, run operators, maintenance personnel together with the completion of the adjustment. Valve adjustment procedure is as follows: 1, the steam boiler when the gas vapor pressure close to the operating pressure of the safety valve, and retest check valve to the air motor exhaust, drainage accident flexibility and reliability of the electric valve, and the panel reinspection situ pressure gauge, the water level of accuracy, such as failure, not allowed to heat the school. 2, ready to call and check the quality of communication tools, a signal indicating whether the good. 3, adjust the safety valves, boiler pressure should be kept stable, pay attention to monitoring gas steam boiler drum level, and maintain normal. 4, steam boiler safety valve to adjust the pressure gauge in place of instructions shall prevail. If necessary using 0.4 or more for the accuracy of the gauge. 5, adjust the safety valve should be carried out only by descending. It should checksum gas steam boiler tuning high pressure safety valve, after the school seizure of the entire set of low pressure relief valve. 6, the following should be in the 0.3MPa, the movement preventing measures must do a good job of setting relatively low pressure steam boiler safety valve safety valve before adjusting. 7, by combustion, and exhaust steam adjust the degree of opening to the air slowly and smoothly up to the required setting pressure. 8, when the gas pressure steam boiler safety valve set pressure to rise if action is normal, then the action and reseating pressure values ​​recorded. If action is not correct or not action should be immediately opened to the air exhaust valve, while the combustion boiler weakened, stop boost, and buck 0.3MPa or less, re-adjust the boiler technician as required by maintenance personnel, until the compliance date. (Lead or lag 0.05MPa action is normal). 9, after the completion valve to adjust gas steam boiler, boiler 0.3MPa or less down to the lifting device and can be installed and fastened to the protective cover, a braking measure required under check valve removal, then Articles 7, 8 verify until all required safety valve calibration check is completed. 10, the safety valve to adjust the gas boiler, check the results recorded in the "safety valve to adjust the recording Visa" within the participants should verify the signatures and Internet safety valve input to the corresponding data in the ledger. During operation gas steam boiler, not only to regularly check on the safety valve, at the same time, we must regularly monitor boiler inspection to ensure that the boiler fully meet the safety requirements!

Fangkuai Group insists on using sophisticated equipment and technology to ensure operation accuracy, increase rigidity and surface finish, reduce wear, ensure excellent performance, and ensure stable and reliable manufacturing quality. It has a domestic Class A boiler manufacturing license issued by the General Administration of Quality Supervision, Inspection and Quarantine. It has been based on quality for many years and has obtained a number of authoritative quality certifications.

Free Chat

About Us

Contact Us